AC/DC Power Supplies
Camtec HSE01201 SERIES AC/DC Power Supply
The Camtec HSE01201 Series AC/DC Power Supply is a compact yet powerful 120W solution designed to excel in demanding industrial environments. With up to 91% efficiency, this DIN-rail mounted power supply delivers reliable and stable performance for a wide range of applications, including DC drives, galvanic systems, and UPS systems. Engineered in Germany, it features a robust design optimised for long life under full load conditions.
Read MoreFeatures
- 120 Watts Supply
- TS35mm DIN-Rail. Metal housing
- Up to 91% efficiency
- Galvanic insulated
- Continuous short circuit protected
- Soft start & auto-recovery
Specifications
Selection Table
Technical Illustrations
Downloads
GENERAL | |
---|---|
Output Voltage | See selection table |
AC Input Voltage | 85..132Vac / 184..265Vac |
Frequency | 47…63Hz |
DC Input Voltage | 110…375Vdc |
AC Input Current | 115Vac <2.2A 230Vac <1.1A |
Factory Adjust. Tolerance Uout | 115Vac <2.2A 230Vac <1.1A |
Load regulation | < ± 0.5% 10-100%, 100-10% |
Switching Frequency | 100KHz typical |
Basic Load | 0 A |
Efficiency | 91% typ. |
Load Protection | 1,2x Irated ,auto recovery |
Voltage Protection | 145% of Uout , auto recovery |
Short Circuit Protection | Continuous |
Temperature Control | Upon request |
Hold Up Time | > 30ms 230Vac |
Inrush Current | < 16A (230Vac) |
Softstart | 50ms typical |
RELIABILITY | |
---|---|
Air & Surface Leakage Paths | > 8mm |
Input / Output Isolation | I/P-O/P:4KVac I/P-G:2KVac O/P-G:0.5KVac |
Power Good Relay (insulated)* | <48Vdc/500mA (not 72V, 110V) |
MTBF | EN61209: 600000h |
MTTF EN61209.SN29500 | 149600h @ 40°C 24/7 85% Load |
ENVIRONMENTAL | |
---|---|
Cooling | Natural convection |
Ambient Temperature | Natural convection |
Storage Temperature | - 40°C…+85°C |
Clima/Dirt/Hight/Humidity | 3k3, Kl.2, 3000m NN, 90% Hum. |
STANDARDS AND APPROVALS | |
---|---|
EMI | EN55022 class B / EN61000-3-2 |
EMS | EN61000-6-2,3 |
Safety | EN60950-1, EN60204-1 |
Safety class 1(A) | VDE0805, VDE0100 |
MECHANICAL | |
---|---|
Dimensions (HxWxD) | 124x50x96mm |
Weight | 510g |
Connectors (AC & DC) | Terminal plug AWG26...AWG12 |
MODEL | HSE01201.12T | HSE01201.24T | HSE01201.36T | HSE01201.48T | HSE01201.60T | HSE01201.72T | HSE01201.110T |
---|---|---|---|---|---|---|---|
Rated DC Voltage | 12Vdc | 24Vdc | 36Vdc | 48Vdc | 60Vdc | 72Vdc | 110Vdc |
Nominal Current | 8.0A | 5.0A | 3.3A | 2.5A | 2.0A | 1,7A | 1,1A |
Adjust Range | 11,4 - 13,2V | 22,5 - 28,5V | 34,2 - 39,6V | 45,6 - 52,8V | 57 - 66V | 68 - 86V | 100 - 120V |
Ripple (230Vac/20MHz) | 50mVpp | 65mVpp | 65mVpp | 100mVpp | 120mVpp | 120mVpp | 200mVpp |
Notes: | Options for telecom & military use available upon request |


GENERAL | |
---|---|
Output Voltage | See selection table |
AC Input Voltage | 85..132Vac / 184..265Vac |
Frequency | 47…63Hz |
DC Input Voltage | 110…375Vdc |
AC Input Current | 115Vac <2.2A 230Vac <1.1A |
Factory Adjust. Tolerance Uout | 115Vac <2.2A 230Vac <1.1A |
Load regulation | < ± 0.5% 10-100%, 100-10% |
Switching Frequency | 100KHz typical |
Basic Load | 0 A |
Efficiency | 91% typ. |
Load Protection | 1,2x Irated ,auto recovery |
Voltage Protection | 145% of Uout , auto recovery |
Short Circuit Protection | Continuous |
Temperature Control | Upon request |
Hold Up Time | > 30ms 230Vac |
Inrush Current | < 16A (230Vac) |
Softstart | 50ms typical |
RELIABILITY | |
---|---|
Air & Surface Leakage Paths | > 8mm |
Input / Output Isolation | I/P-O/P:4KVac I/P-G:2KVac O/P-G:0.5KVac |
Power Good Relay (insulated)* | <48Vdc/500mA (not 72V, 110V) |
MTBF | EN61209: 600000h |
MTTF EN61209.SN29500 | 149600h @ 40°C 24/7 85% Load |
ENVIRONMENTAL | |
---|---|
Cooling | Natural convection |
Ambient Temperature | Natural convection |
Storage Temperature | - 40°C…+85°C |
Clima/Dirt/Hight/Humidity | 3k3, Kl.2, 3000m NN, 90% Hum. |
STANDARDS AND APPROVALS | |
---|---|
EMI | EN55022 class B / EN61000-3-2 |
EMS | EN61000-6-2,3 |
Safety | EN60950-1, EN60204-1 |
Safety class 1(A) | VDE0805, VDE0100 |
MECHANICAL | |
---|---|
Dimensions (HxWxD) | 124x50x96mm |
Weight | 510g |
Connectors (AC & DC) | Terminal plug AWG26...AWG12 |
MODEL | HSE01201.12T | HSE01201.24T | HSE01201.36T | HSE01201.48T | HSE01201.60T | HSE01201.72T | HSE01201.110T |
---|---|---|---|---|---|---|---|
Rated DC Voltage | 12Vdc | 24Vdc | 36Vdc | 48Vdc | 60Vdc | 72Vdc | 110Vdc |
Nominal Current | 8.0A | 5.0A | 3.3A | 2.5A | 2.0A | 1,7A | 1,1A |
Adjust Range | 11,4 - 13,2V | 22,5 - 28,5V | 34,2 - 39,6V | 45,6 - 52,8V | 57 - 66V | 68 - 86V | 100 - 120V |
Ripple (230Vac/20MHz) | 50mVpp | 65mVpp | 65mVpp | 100mVpp | 120mVpp | 120mVpp | 200mVpp |
Notes: | Options for telecom & military use available upon request |


Find the Right Model
Model Number | Input Voltage (Vac) | Output Voltage (Vdc) | Output Current (A) | ||
---|---|---|---|---|---|
![]() |
HSE01201.12T(R2) | 90...132Vac / 184...264Vac 50/60Hz (Switch Selectable) | 12Vdc (Adj. 11.4 - 13.2Vdc) | 8A | |
![]() |
HSE01201.15T(R2) | 90...132Vac / 184...264Vac 50/60Hz (Switch Selectable) | 15Vdc (Adj. 14.2 - 16.5Vdc) | 8A | |
![]() |
HSE01201.24T(R2) | 90...132Vac / 184...264Vac 50/60Hz (Switch Selectable) | 24Vdc (Adj. 23.5 - 28.5Vdc) | 5A | |
![]() |
HSE01201.36T(R2) | 90...132Vac / 184...264Vac 50/60Hz (Switch Selectable) | 36Vdc (Adj. 34.2 - 39.6Vdc) | 3.3A | |
![]() |
HSE01201.48T(R2) | 90...132Vac / 184...264Vac 50/60Hz (Switch Selectable) | 48Vdc (Adj. 45.6 - 52.8Vdc) | 2.5A | |
![]() |
HSE01201.60T(R2) | 90...132Vac / 184...264Vac 50/60Hz (Switch Selectable) | 60Vdc (Adj. 57 - 66Vdc) | 2A | |
![]() |
HSE01201.72T(R2) | 90...132Vac / 184...264Vac 50/60Hz (Switch Selectable) | 72Vdc (Adj. 68 - 86Vdc) | 1.7A | |
![]() |
HSE01201.110T(R2) | 90...132Vac / 184...264Vac 50/60Hz (Switch Selectable) | 110Vdc (Adj. 100 - 120Vdc) | 1.1A |
Need help finding the right product model?