Polarium SLB48-150-145-5 | 48V | 150Ah | Lithium-ion Battery
The Polarium SLB48-150-145-5 is a high-capacity 48 V, 150 Ah lithium-ion backup battery engineered for operators requiring dependable energy storage across telecommunications networks, hybrid power systems, industrial infrastructure, and remote environments. Built on Polarium’s fifth-generation LFP platform, this 19-inch 4U module delivers stable long-term performance with a rated energy capacity of 7.2 kWh and a durable iron-based chemistry optimised for demanding backup applications.
Read MoreFeatures
- High-Capacity LFP Energy Storage - Delivers 150 Ah of rated capacity and 7.2 kWh of usable energy, providing extended backup time for telecommunications, industrial networks, and remote sites that require longer autonomy during outages.
- Durable Cycle Performance - Designed for long-term operation with up to 6000 cycles at 0.5C and 80% SOH, supporting frequent cycling in hybrid power systems and renewable-assisted sites where batteries regularly charge and discharge.
- Wide Environmental Operating Range - Supports discharging down to –20 °C and up to +60 °C, with charging available from 0 °C to +55 °C. This range enables dependable operation in Australian climate conditions and thermally variable enclosures.
- Integrated Battery Protection & Safety Controls - A built-in, BMS-controlled 100 A circuit breaker supports safe operation, along with protections for cell voltage, current, and temperature. Safety certifications include IEC62619, IEC62368, and UN38.3. The BMS includes automatic reconnect behaviour after safe conditions return.
- Smart Monitoring & System Intelligence - Equipped with dual RS485/RJ45 ports and Modbus communication, the battery supports local and remote monitoring through Polarium Studio software. Automatic cell balancing and system supervision maintain stable performance across its lifecycle.
- Secure Installation with Anti-Theft Capability - The module includes Polarium’s patented Anti-Theft Device, which disables battery operation if removed from the site, helping prevent unauthorised use.
Specifications
Technical Illustrations
Downloads
| TECHNICAL SPECIFICATIONS | |
|---|---|
| Enclosure Size | 19" 4U |
| Lithium chemistry | LFP |
| Rated Voltage | 48 V |
| Rated Capacity Ah (0.2C, 25°C to LVBD) | 150 Ah |
| Rated Energy Wh (0.2C, 25°C to LVBD) | 7200 Wh |
| Calendar Life @ 80% SOC | 15 years |
| Cycle Life | 6000 cycles, 0.5C, 25 °C, SOH 80% |
| Peak Discharge Power | 6kW for 60 seconds |
| Discharge Cutoff Current | 100 A |
| End-of-Discharge Voltage (LVBD)* | 40 V |
| Charge Current Limitation (CLD)** | 100 A |
| Charge Voltage for 100% SOC | 54.75 V |
| Min Charging Voltage | 52.5 V |
| Operating Temperature Charging | 0 to +55 °C (32 to 131 °F) |
| Operating Temperature Discharging | -20 to +60 °C (-4 to 140 °F) |
| Operating Relative Humidity | According to ETSI 300 019-1-3 class 3.2 (0-95%) |
| Storage Temperature | -20 to +60°C (-4 to 140°F) |
| Weight | Approx. 58.6 Kg (129 lbs) |
| Dimensions mm (in") |
W 440 D 475 H 177.4 mm |
| Circuit breaker | 100 A, BMS Controlled, single pole |
| IP class | IP20 |
| Communication Protocols | RS485, RJ45 (2) ports, Modbus |
| Safety Standards | IEC62619, IEC62368, UN38.3 |
| Management & Monitoring | Software for PC (Studio) included for full local monitoring and management. Remote connection via Modbus |
| *Cut off when one cell reaches 2.5 V, 15 cells in series whatever comes first. Data subject to change without notice **If the charge current is 100 A or higher, the battery will automatically reduce the charge current to 6-12 A temporarily. Data subject to change without notice |
|
| TECHNICAL SPECIFICATIONS | |
|---|---|
| Enclosure Size | 19" 4U |
| Lithium chemistry | LFP |
| Rated Voltage | 48 V |
| Rated Capacity Ah (0.2C, 25°C to LVBD) | 150 Ah |
| Rated Energy Wh (0.2C, 25°C to LVBD) | 7200 Wh |
| Calendar Life @ 80% SOC | 15 years |
| Cycle Life | 6000 cycles, 0.5C, 25 °C, SOH 80% |
| Peak Discharge Power | 6kW for 60 seconds |
| Discharge Cutoff Current | 100 A |
| End-of-Discharge Voltage (LVBD)* | 40 V |
| Charge Current Limitation (CLD)** | 100 A |
| Charge Voltage for 100% SOC | 54.75 V |
| Min Charging Voltage | 52.5 V |
| Operating Temperature Charging | 0 to +55 °C (32 to 131 °F) |
| Operating Temperature Discharging | -20 to +60 °C (-4 to 140 °F) |
| Operating Relative Humidity | According to ETSI 300 019-1-3 class 3.2 (0-95%) |
| Storage Temperature | -20 to +60°C (-4 to 140°F) |
| Weight | Approx. 58.6 Kg (129 lbs) |
| Dimensions mm (in") |
W 440 D 475 H 177.4 mm |
| Circuit breaker | 100 A, BMS Controlled, single pole |
| IP class | IP20 |
| Communication Protocols | RS485, RJ45 (2) ports, Modbus |
| Safety Standards | IEC62619, IEC62368, UN38.3 |
| Management & Monitoring | Software for PC (Studio) included for full local monitoring and management. Remote connection via Modbus |
| *Cut off when one cell reaches 2.5 V, 15 cells in series whatever comes first. Data subject to change without notice **If the charge current is 100 A or higher, the battery will automatically reduce the charge current to 6-12 A temporarily. Data subject to change without notice |
|
Find the Right Model
| Model Number | Rated Voltage (Vdc) | Rated Capacity (Ah) | Rated Energy (Wh) | ||
|---|---|---|---|---|---|
|
SLB48-150-145-5 | 48Vdc | 150Ah | 7200Wh |
Need help finding the right product model?