Delta Electronics PMT2 150W Series Panel Mount AC/DC Power Supply
The Delta PMT2 150W Series is a range of low-profile, high-reliability panel mount AC-DC power supplies designed for industrial control, automation, instrumentation, and ITE applications where space, safety compliance, and long service life are critical. Featuring a slim 30 mm enclosure and selectable universal AC input (90–132 Vac / 180–264 Vac...
Read MoreThe Delta PMT2 150W Series is a range of low-profile, high-reliability panel mount AC-DC power supplies designed for industrial control, automation, instrumentation, and ITE applications where space, safety compliance, and long service life are critical.
Featuring a slim 30 mm enclosure and selectable universal AC input (90–132 Vac / 180–264 Vac), the PMT2 150W Series integrates easily into compact electrical panels and OEM systems. Single-output DC voltage options allow flexibility across a wide range of industrial loads while maintaining clean, regulated power delivery.
Built for demanding environments, the PMT2 150W Series operates from -30°C to +70°C with fanless convection cooling and supports -40°C cold start, ensuring reliable performance in harsh conditions. High efficiency, combined with ultra-low no-load power consumption (<0.5 W), helps reduce internal heat and improve system longevity.
Certified to IEC/EN/UL 62368-1, IEC/EN 60335-1, and IEC/EN 61558-1 / -2-16, the PMT2 150W Series meets global safety and EMC requirements for industrial and commercial equipment. Supported locally by Powerbox, it provides a dependable, long-life power solution for modern control and automation systems.
Show Less
Features
- Selectable AC Input Range: 90–132 Vac / 180–264 Vac via onboard switch
- Output Voltage Options: 12, 15, 24, 30, 36 and 48 Vdc
- Rated Output Current: Up to 12.5 A (model dependent)
- 150 W Single Output Panel Mount Power Supplies
- Low-Profile Design: Only 30 mm height for compact enclosures
- Wide Operating Temperature: -30°C to +70°C (-40°C cold start support)
- High Efficiency & Low Standby Power: < 0.5 W no-load consumption
- Fanless Convection Cooling: Quiet, maintenance-free operation
- Adjustable Output Voltage: Supports voltage trimming and cable-drop compensation
- Industrial Safety & EMC Compliance: IEC/EN/UL 62368-1, IEC/EN 60335-1, IEC/EN 61558-1 / -2-16, AS/NZS CISPR 32
- Status Indication: Green DC OK LED
- High Reliability: MTBF >700,000 hours (Telcordia SR-332)
Specifications
| INPUT RATINGS/CHARACTERISTICS | ||||||
|---|---|---|---|---|---|---|
| Model Number | PMT-12V150W2BA | PMT-15V150W2BA | PMT-24V150W2BA |
PMT-30V150W2BA |
PMT-36V150W2BA | PMT-48V150W2BA |
| Nominal Input Voltage | 100-120 Vac, 200-240 Vac (Selectable by Switch) | |||||
| Input Voltage Range | 90-132 Vac, 180-264 Vac (Selectable by Switch) | |||||
| Nominal Input Frequency | 50...60 Hz | |||||
| Input Frequency Range | 47...63 Hz | |||||
| Input Current | 3 A typ. @ 115 Vac, 1.7 A typ. @ 230 Vac | |||||
| Efficiency at 100% Load @230Vac | 87.5% typ. | 88.0% typ. | 89% typ. | 89% typ. | 89.5% typ. | 91% typ. |
| No Load Power Consumption | < 0.5 W @ 230 Vac | |||||
| Max Inrush Current (Cold Start) | 60 A typ. @ 230 Vac | |||||
| Leakage Current | < 0.5 mA @ 240 Vac | |||||
| OUTPUT RATINGS/CHARACTERISTICS*² | ||||||
|---|---|---|---|---|---|---|
| Model Number | PMT-12V150W2BA | PMT-15V150W2BA | PMT-24V150W2BA | PMT-30V150W2BA | PMT-36V150W2BA | PMT-48V150W2BA |
| Nominal Output Voltage | 12 Vdc | 15 Vdc | 24 Vdc | 30 Vdc | 36 Vdc | 48 Vdc |
| Factory Set Point Tolerance | 12 Vdc ± 1% | 15 Vdc ± 1% | 24 Vdc ± 1% | 30 Vdc ± 1% | 36 Vdc ± 1% | 48 Vdc ± 1% |
| Output Voltage Adjustment Range | 10.8-13.2 Vdc | 13.5-16.5 Vdc | 21.6-26.4 Vdc | 27.0-33.0 Vdc | 32.4-39.6 Vdc | 43.2-52.8 Vdc |
| Output Current | 12.5 A | 10.0 A | 6.25 A | 5.00 A | 4.30 A | 3.30 A |
| Output Power | 150 W Max. | 150 W Max. | 150 W Max. | 150 W Max. | 154.8 W Max. | 158.4 W Max. |
| Line Regulation | ± 0.5% typ. @ 100-132 Vac, 180-264 Vac (Selectable by Switch) | |||||
| Load Regulation | ± 0.5% typ. @ 100-132 Vac, 180-264 Vac (Selectable by Switch) | |||||
| PARD*³ (20MHz) | < 150 mVpp @ 0°C to 70°C, 450 mVpp typ. @ -30°C to 0°C |
< 200 mVpp @ 0°C to 70°C, 600 mVpp typ. @ -30°C to 0°C |
||||
| Rise Time | 30 ms typ. @ 115 Vac & 230 Vac | |||||
| Start-up Time | 500 ms typ. @ 115 Vac & 230 Vac | |||||
| Hold-up Time | 30 ms typ. @ 115 Vac & 230 Vac | |||||
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 10% @ 115 & 230 Vac input, 10-100% load (Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 KHz) | |||||
| Start-up with Capacitive Loads | 8,000μF Max | 8,000μF Max | 8,000μF Max | 6,000μF Max | 3,000μF Max | 2,000μF Max |
| *2 For power de-rating from > 50°C to 70°C, see power de-rating on page 3. *3 PARD is measured with an AC coupling mode, and in parallel to end terminal with 0.1μF ceramic capacitor & 47μF electrolytic capacitor. PSU need to burn in > 5 minutes when AMB ≤ 0℃ |
||||||
| MECHANICAL | |||||||
|---|---|---|---|---|---|---|---|
| Model Number | PMT-12V150W2BA | PMT-15V150W2BA | PMT-24V150W2BA |
PMT-30V150W2BA |
PMT-36V150W2BA |
PMT-48V150W2BA |
|
| Case Chassis | Aluminum | ||||||
| Case Cover | SGCC | ||||||
| Dimensions (L x W x H) | 159 x 97 x 30 mm (6.26 x 3.82 x 1.18 inch) | ||||||
| Unit Weight | 0.354 kg (0.78 lb) | ||||||
| Indicator | Green LED (DC OK) | ||||||
| Cooling System | Convection | ||||||
| Terminal | M3.5 x 7 Pins (Rated 300 V / 20 A) | ||||||
| Wire | AWG 18-12 Current rating can refer to page 6 “Wire AWG Table” |
||||||
| Noise (1 Meter from power supply) | Sound Pressure Level (SPL) < 25 dBA | ||||||
| ENVIRONMENT | |||||||
|---|---|---|---|---|---|---|---|
| Model Number | PMT-12V150W2BA | PMT-15V150W2BA | PMT-24V150W2BA |
PMT-30V150W2BA |
PMT-36V150W2BA |
PMT-48V150W2BA | |
| Surrounding Air Temperature | Operating | -30°C to +70°C (-40°C Cold Start) | |||||
| Storage | -40°C to +85°C | ||||||
| Power De-rating | > 50°C de-rate power by 2% / °C < -25°C de-rate power by 4% / °C @ 100 Vac < 100 Vac de-rate power by 1.33% / V (86.67% load @ 90 Vac |
||||||
| Operating Humidity | 20 to 90% RH (Non-Condensing) | ||||||
| Operating Altitude | 0 to 5,000 Meters (0 to 16,400 ft) | ||||||
| Shock Test | Non- Operating | IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11 ms, 3 shocks for each 3 directions | |||||
| Operating | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11 ms, 3 shock for each 3 directions. | ||||||
| Vibration | Non- Operating | IEC 60068-2-6, Random: 5 Hz to 500 Hz (2.09G); 20 min per axis for all X, Y, Z direction |
|||||
| Operating | IEC 60068-2-6, Sine Wave: 20 Hz to 500 Hz (5G); 10 min per cycle, 60min for each axis (X, Y,Z) |
||||||
| Over Voltage Category | II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) | ||||||
| Pollution Degree | 3 | ||||||
| PROTECTIONS | ||||||
|---|---|---|---|---|---|---|
| Model Number | PMT-12V150W2BA | PMT-15V150W2BA | PMT-24V150W2BA |
PMT-30V150W2BA |
PMT-36V150W2BA |
PMT-48V150W2BA |
| Overvoltage |
13.2 V - 17.4 V SELV Output, Latch Mode |
16.5 V - 21.0 V SELV Output, Latch Mode |
26.4V - 33.6 V |
33.0 V - 40.5 V SELV Output, Latch Mode |
39.6 V - 48.6 V SELV Output, Latch Mode |
52.8 V - 64.8 V SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) | |||||
| Over Temperature | Latch Mode | |||||
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
|||||
| Protection Against Shock | Class I with PE*⁴ connection | |||||
| *4 PE: Primary Earth | ||||||
| RELIABILITY DATA | ||||||
|---|---|---|---|---|---|---|
| Model Number | PMT-12V150W2BA | PMT-15V150W2BA |
PMT-24V150W2BA |
PMT-30V150W2BA |
PMT-36V150W2BA |
PMT-48V150W2BA |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230 Vac, O/P: 100% Load, Ta: 25°C) |
|||||
| Expected Cap Life Time | 10 years (230 Vac, 50% load @ 40°C) | |||||
| SAFETY STANDARDS/DIRECTIVES | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model Number | PMT-12V150W2BA | PMT-15V150W2BA | PMT-24V150W2BA | PMT-30V150W2BA | PMT-36V150W2BA | PMT-48V150W2BA | ||||||
| Safety Entry Low Voltage | SELV | |||||||||||
| Electrical Safety | TUV Bauart | EN 62368-1, EN60335-1, EN 61558-1/-2-16 | ||||||||||
| cULus | UL 62368-1, and CAN/CSA C22.2 No. 62368-1 | |||||||||||
| CB scheme | IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16 | |||||||||||
| CCC | GB 4943.1 | |||||||||||
| KC | K 60950-1 | |||||||||||
| EAC | TP TC 004/2011 | |||||||||||
| BSMI | CNS 14336-1 | |||||||||||
| BIS | IS 13252 (Part 1) | |||||||||||
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU | |||||||||||
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016 | |||||||||||
| Galvanic Isolation | Input to Output | 4.0 kVac | ||||||||||
| Input to Ground | 2.0 kVac | |||||||||||
| Output to Ground | 1.25 kVac | |||||||||||
| EMC | ||||
|---|---|---|---|---|
| Emissions (CE & RE) | CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR32 Compliance to EN/BS EN 55014-1, FCC Title 47, EN/BS EN 61000-6-3 : Class B | |||
| Immunity | EN/BS EN 55035, KN35, EN/BS EN 61000-6-2 Compliance to EN/BS EN 55014-2,EN/BS EN 61000-6-1 |
|||
| Electrostatic Discharge | IEC 61000-4-2 |
Level 4 Criteria A¹⁾ |
||
| Radiated Field | IEC 61000-4-3 |
Level 3 Criteria A¹⁾ |
||
| Electrical Fast Transient / Burst | IEC 61000-4-4 |
Level 3 Criteria A¹⁾ |
||
| Surge | IEC 61000-4-5 |
Level 4 Criteria A¹⁾ |
||
| Conducted | IEC 61000-4-6 | Level 3 Criteria A¹⁾ 150 kHz – 80 MHz, 10 Vrms |
||
| Power Frequency Magnetic Fields | IEC 61000-4-8 | Level 4 Criteria A¹⁾ 30 A/meter |
||
| Voltage Dips and Interruptions | IEC 61000-4-11 | 0% residual; 1 cycle, Criteria B 40% residual; 10 cycle, Criteria C³⁾ 70% residual; 25 cycle, Criteria C³⁾ |
||
| Harmonic Current Emission | IEC/EN/BS EN 61000-3-2 | Class A | ||
| 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test. 3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test) 4) Asymmetrical: Common mode (Line to earth) 5) Symmetrical: Differential mode (Line to line) |
||||
Selection Table
| MODEL NUMBER | INPUT VOLTAGE RANGE | RATED OUTPUT VOLTAGE | RATED OUTPUT CURRENT |
|---|---|---|---|
| PMT-12V150W2BA |
90-132 Vac, 180-264 Vac (Selectable by Switch) |
12Vdc | 12.5 A |
| PMT-15V150W2BA | 15Vdc | 10.0 A | |
| PMT-24V150W2BA | 24Vdc | 6.25 A | |
| PMT-30V150W2BA | 30Vdc | 5.0 A | |
| PMT-36V150W2BA | 36Vdc | 4.3 A | |
| PMT-48V150W2BA | 48Vdc | 3.3 A |
Technical Drawings
Warranty & Returns
Warranty periods vary by product. Please refer to the Powerbox Warranty Policy for the applicable coverage period against manufacturing defects from date of purchase. For returns and RMA requests, please visit our RMA support page or contact our support team directly.