Delta Electronics PMT2 200W Series Panel Mount AC/DC Power Supply
The Delta PMT2 200W Series is a range of high-power, low-profile panel mount AC-DC power supplies designed for industrial control, automation, instrumentation, and information technology equipment where higher output capacity, reliability, and safety compliance are essential.
Read MoreFeatures
- Selectable AC Input Range: 90–132 Vac / 180–264 Vac via onboard switch
- Output Voltage Options: 12, 24, 36 and 48 Vdc
- Rated Output Current: Up to 17.0 A (model dependent)
- 200 W Single Output Panel Mount Power Supplies
- Low-Profile Design: Only 30 mm height for compact enclosures
- Wide Operating Temperature: -40°C to +70°C with cold start support
| INPUT RATINGS/CHARACTERISTICS | ||||
|---|---|---|---|---|
| Model Number | PMT-12V200W2BR | PMT-24V200W2BR |
PMT-36V200W2BR | PMT-48V200W2BR |
| Nominal Input Voltage | 100-120 Vac, 200-240 Vac (Selectable by Switch) | |||
| Input Voltage Range | 90-132 Vac, 180-264 Vac (Selectable by Switch) | |||
| Nominal Input Frequency | 50...60 Hz | |||
| Input Frequency Range | 47...63 Hz | |||
| Input Current | 4 A typ. @ 115 Vac, 2.2 A typ. @ 230 Vac | |||
| Efficiency at 100% Load @230Vac | 88.5% typ. | 90.0% typ. | 90.0% typ. | 91.0% typ. |
| No Load Power Consumption | < 0.5 W @ 230 Vac | |||
| Max Inrush Current (Cold Start) | 60 A typ. @ 230 Vac | |||
| Leakage Current | < 0.5 mA @ 240 Vac / 50 Hz | |||
| OUTPUT RATINGS/CHARACTERISTICS*² | ||||
|---|---|---|---|---|
| Model Number | PMT-12V200W2BR | PMT-24V200W2BR | PMT-36V200W2BR | PMT-48V200W2BR |
| Nominal Output Voltage | 12 Vdc | 24 Vdc | 36 Vdc | 48 Vdc |
| Factory Set Point Tolerance | 12 Vdc ± 1% | 24 Vdc ± 1% | 36 Vdc ± 1% | 48 Vdc ± 1% |
| Output Voltage Adjustment Range | 10.8-13.2 Vdc | 21.6-26.4 Vdc | 32.4-39.6 Vdc | 43.2-52.8 Vdc |
| Output Current | 0-17.0 A | 0-8.8 A | 0-5.9 A | 0-4.4 A |
| Output Power | 204 W Max. | 211.2 W Max. | 212.4 W Max. | 211.2 W Max. |
| Line Regulation | ± 0.5% typ. @ 100-132 Vac, 180-264 Vac (Selectable by Switch) | |||
| Load Regulation | ± 1% typ. @ 100-132 Vac, 180-264 Vac (Selectable by Switch) |
± 0.5% typ. @ 100-132 Vac, 180-264 Vac (Selectable by Switch) | ||
| PARD*³ (20MHz) | < 150 mVpp @ 0°C to 70°C, 450 mVpp typ. @ -30°C to 0°C |
< 200 mVpp @ 0°C to 70°C, 600 mVpp typ. @ -30°C to 0°C |
||
| Rise Time | 30 ms typ. @ 115 Vac & 230 Vac | |||
| Start-up Time | 500 ms typ. @ 115 Vac & 230 Vac | |||
| Hold-up Time | 30 ms typ. @ 115 Vac & 230 Vac | |||
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 10% @ 115 & 230 Vac input, 10-100% load (Slew Rate: 2.5 A / μS, 50% duty cycle @ 5 Hz & 10 KHz) | |||
| Start-up with Capacitive Loads | 8,000μF Max | 8,000μF Max | 3,000μF Max | 2,000μF Max |
| *2 For power de-rating from > 50°C to 70°C, see power de-rating on page 3. *3 PARD is measured with an AC coupling mode, and in parallel to end terminal with 0.1μF ceramic capacitor & 47μF electrolytic capacitor. PSU need to burn in > 5 minutes when AMB ≤ 0℃ |
||||
| MECHANICAL | |||||
|---|---|---|---|---|---|
| Model Number | PMT-12V200W2BR | PMT-24V200W2BR |
PMT-36V200W2BR |
PMT-48V200W2BR |
|
| Case Chassis | Aluminum | ||||
| Case Cover | SGCC | ||||
| Dimensions (L x W x H) | 159 x 97 x 30 mm (6.26 x 3.82 x 1.18 inch) | ||||
| Unit Weight | 0.42 kg (0.926 lb) | ||||
| Indicator | Green LED (DC OK) | ||||
| Cooling System | Convection | ||||
| Terminal | M 3.5 x 7 Pins (Rated 300 V / 20 A) | ||||
| Wire | AWG 18-12 Current rating can refer to page 6 “Wire AWG Table” |
||||
| Noise (1 Meter from power supply) | Sound Pressure Level (SPL) < 25 dBA | ||||
| ENVIRONMENT | |||||
|---|---|---|---|---|---|
| Model Number | PMT-12V200W2BR | PMT-24V200W2BR |
PMT-36V200W2BR |
PMT-48V200W2BR | |
| Surrounding Air Temperature | Operating | -30°C to +70°C | |||
| Storage | -40°C to +85°C | ||||
| Power De-rating | > 50°C de-rate power by 2% / °C < 100 Vac de-rate power by 2% / V (80% load@ 90 Vac) |
||||
| Operating Humidity | 20 to 90% RH (Non-Condensing) | ||||
| Operating Altitude | 0 to 5,000 Meters (0 to 16,400 ft) | ||||
| Shock Test | Non- Operating | IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions | |||
| Operating | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. | ||||
| Vibration | Non- Operating | IEC 60068-2-6, Random: 5 Hz to 500 Hz (2.09G); 20 min per axis for all X, Y, Z direction |
|||
| Operating | IEC 60068-2-6, Sine Wave: 20Hz to 500 Hz (5G); 10 min per cycle, 60 min for each axis (X, Y, Z) |
||||
| Over Voltage Category | II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) | ||||
| Pollution Degree | 3 | ||||
| PROTECTIONS | ||||
|---|---|---|---|---|
| Model Number | PMT-12V200W2BR | PMT-24V200W2BR |
PMT-36V200W2BR |
PMT-48V200W2BR |
| Overvoltage |
13.2 V - 17.4 V SELV Output, Latch Mode |
26.4V - 33.6 V |
39.6 V - 48.6 V SELV Output, Latch Mode |
52.8 V - 64.8 V SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) | |||
| Over Temperature | Latch Mode | |||
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
|||
| Protection Against Shock | Class I with PE*⁴ connection | |||
| *4 PE: Primary Earth | ||||
| RELIABILITY DATA | ||||
|---|---|---|---|---|
| Model Number | PMT-12V200W2BR | PMT-24V200W2BR |
PMT-36V200W2BR |
PMT-48V200W2BR |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230 Vac, O/P: 100% Load, Ta: 25°C) |
|||
| Expected Cap Life Time | 10 years (230 Vac, 50% load @ 40°C) | |||
| SAFETY STANDARDS/DIRECTIVES | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Model Number | PMT-12V200W2BR | PMT-24V200W2BR | PMT-36V200W2BR | PMT-48V200W2BR | ||||||
| Safety Entry Low Voltage | SELV | |||||||||
| Electrical Safety | TUV Bauart | EN 62368-1,EN 60335-1, EN 61558-1/-2-16 | ||||||||
| cULus | UL 62368-1, and CAN/CSA C22.2 No. 62368-1 | |||||||||
| CB scheme | IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16 | |||||||||
| KC | K 60950-1 (12 & 24 V model) | |||||||||
| EAC | TP TC 004/2011 | |||||||||
| BSMI | CNS 14336-1 | |||||||||
| BIS | IS 13252 (Part 1) | |||||||||
| CCC | GB 4943.1 | |||||||||
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU This power supply does not comply with the harmonic current emission requirements specified in BS EN/EN61000-3-2. Please ensure it is not used in applications where compliance with this standard is required |
|||||||||
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016 | |||||||||
| Galvanic Isolation | Input to Output | 4.0 kVac | ||||||||
| Input to Ground | 2.0 kVac | |||||||||
| Output to Ground | 1.25 kVac | |||||||||
| EMC | ||||
|---|---|---|---|---|
| Emissions (CE & RE) | CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR 32 Compliance to EN/BS EN 55014-1, FCC Title 47, EN/BS EN 61000-6-3 : Class B |
|||
| Immunity | EN/BS EN 55035, KN35, EN/BS EN 61000-6-2 & Compliance to EN/BS EN 55014-2,EN/BS EN 61000-6-1 | |||
| Electrostatic Discharge | IEC 61000-4-2 |
Level 4 Criteria A¹⁾ |
||
| Radiated Field | IEC 61000-4-3 |
Level 3 Criteria A¹⁾ |
||
| Electrical Fast Transient / Burst | IEC 61000-4-4 |
Level 3 Criteria A¹⁾ |
||
| Surge | IEC 61000-4-5 |
Level 4 Criteria A¹⁾ |
||
| Conducted | IEC 61000-4-6 | Level 3 Criteria A¹⁾ 150 kHz – 80 MHz, 10 Vrms |
||
| Power Frequency Magnetic Fields | IEC 61000-4-8 | Level 4 Criteria A¹⁾ 30 A/meter |
||
| Voltage Dips and Interruptions | IEC 61000-4-11 | 0% residual; 1 cycle, Criteria B 40% residual; 10 cycle, Criteria C³⁾ 70% residual; 25 cycle, Criteria C³⁾ |
||
| Harmonic Current Emission | IEC/EN/BS EN 61000-3-2 | Class A | ||
| 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test. 3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test) 4) Asymmetrical: Common mode (Line to earth) 5) Symmetrical: Differential mode (Line to line) |
||||
| MODEL NUMBER | INPUT VOLTAGE RANGE | RATED OUTPUT VOLTAGE | RATED OUTPUT CURRENT |
|---|---|---|---|
| PMT-12V200W2BR |
90-132 Vac, 180-264 Vac (Selectable by Switch) |
12Vdc | 17.0 A |
| PMT-24V200W2BR | 24Vdc | 8.8 A | |
| PMT-36V200W2BR | 36Vdc | 5.9 A | |
| PMT-48V200W2BR | 48Vdc | 4.4 A |
| INPUT RATINGS/CHARACTERISTICS | ||||
|---|---|---|---|---|
| Model Number | PMT-12V200W2BR | PMT-24V200W2BR |
PMT-36V200W2BR | PMT-48V200W2BR |
| Nominal Input Voltage | 100-120 Vac, 200-240 Vac (Selectable by Switch) | |||
| Input Voltage Range | 90-132 Vac, 180-264 Vac (Selectable by Switch) | |||
| Nominal Input Frequency | 50...60 Hz | |||
| Input Frequency Range | 47...63 Hz | |||
| Input Current | 4 A typ. @ 115 Vac, 2.2 A typ. @ 230 Vac | |||
| Efficiency at 100% Load @230Vac | 88.5% typ. | 90.0% typ. | 90.0% typ. | 91.0% typ. |
| No Load Power Consumption | < 0.5 W @ 230 Vac | |||
| Max Inrush Current (Cold Start) | 60 A typ. @ 230 Vac | |||
| Leakage Current | < 0.5 mA @ 240 Vac / 50 Hz | |||
| OUTPUT RATINGS/CHARACTERISTICS*² | ||||
|---|---|---|---|---|
| Model Number | PMT-12V200W2BR | PMT-24V200W2BR | PMT-36V200W2BR | PMT-48V200W2BR |
| Nominal Output Voltage | 12 Vdc | 24 Vdc | 36 Vdc | 48 Vdc |
| Factory Set Point Tolerance | 12 Vdc ± 1% | 24 Vdc ± 1% | 36 Vdc ± 1% | 48 Vdc ± 1% |
| Output Voltage Adjustment Range | 10.8-13.2 Vdc | 21.6-26.4 Vdc | 32.4-39.6 Vdc | 43.2-52.8 Vdc |
| Output Current | 0-17.0 A | 0-8.8 A | 0-5.9 A | 0-4.4 A |
| Output Power | 204 W Max. | 211.2 W Max. | 212.4 W Max. | 211.2 W Max. |
| Line Regulation | ± 0.5% typ. @ 100-132 Vac, 180-264 Vac (Selectable by Switch) | |||
| Load Regulation | ± 1% typ. @ 100-132 Vac, 180-264 Vac (Selectable by Switch) |
± 0.5% typ. @ 100-132 Vac, 180-264 Vac (Selectable by Switch) | ||
| PARD*³ (20MHz) | < 150 mVpp @ 0°C to 70°C, 450 mVpp typ. @ -30°C to 0°C |
< 200 mVpp @ 0°C to 70°C, 600 mVpp typ. @ -30°C to 0°C |
||
| Rise Time | 30 ms typ. @ 115 Vac & 230 Vac | |||
| Start-up Time | 500 ms typ. @ 115 Vac & 230 Vac | |||
| Hold-up Time | 30 ms typ. @ 115 Vac & 230 Vac | |||
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 10% @ 115 & 230 Vac input, 10-100% load (Slew Rate: 2.5 A / μS, 50% duty cycle @ 5 Hz & 10 KHz) | |||
| Start-up with Capacitive Loads | 8,000μF Max | 8,000μF Max | 3,000μF Max | 2,000μF Max |
| *2 For power de-rating from > 50°C to 70°C, see power de-rating on page 3. *3 PARD is measured with an AC coupling mode, and in parallel to end terminal with 0.1μF ceramic capacitor & 47μF electrolytic capacitor. PSU need to burn in > 5 minutes when AMB ≤ 0℃ |
||||
| MECHANICAL | |||||
|---|---|---|---|---|---|
| Model Number | PMT-12V200W2BR | PMT-24V200W2BR |
PMT-36V200W2BR |
PMT-48V200W2BR |
|
| Case Chassis | Aluminum | ||||
| Case Cover | SGCC | ||||
| Dimensions (L x W x H) | 159 x 97 x 30 mm (6.26 x 3.82 x 1.18 inch) | ||||
| Unit Weight | 0.42 kg (0.926 lb) | ||||
| Indicator | Green LED (DC OK) | ||||
| Cooling System | Convection | ||||
| Terminal | M 3.5 x 7 Pins (Rated 300 V / 20 A) | ||||
| Wire | AWG 18-12 Current rating can refer to page 6 “Wire AWG Table” |
||||
| Noise (1 Meter from power supply) | Sound Pressure Level (SPL) < 25 dBA | ||||
| ENVIRONMENT | |||||
|---|---|---|---|---|---|
| Model Number | PMT-12V200W2BR | PMT-24V200W2BR |
PMT-36V200W2BR |
PMT-48V200W2BR | |
| Surrounding Air Temperature | Operating | -30°C to +70°C | |||
| Storage | -40°C to +85°C | ||||
| Power De-rating | > 50°C de-rate power by 2% / °C < 100 Vac de-rate power by 2% / V (80% load@ 90 Vac) |
||||
| Operating Humidity | 20 to 90% RH (Non-Condensing) | ||||
| Operating Altitude | 0 to 5,000 Meters (0 to 16,400 ft) | ||||
| Shock Test | Non- Operating | IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions | |||
| Operating | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. | ||||
| Vibration | Non- Operating | IEC 60068-2-6, Random: 5 Hz to 500 Hz (2.09G); 20 min per axis for all X, Y, Z direction |
|||
| Operating | IEC 60068-2-6, Sine Wave: 20Hz to 500 Hz (5G); 10 min per cycle, 60 min for each axis (X, Y, Z) |
||||
| Over Voltage Category | II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) | ||||
| Pollution Degree | 3 | ||||
| PROTECTIONS | ||||
|---|---|---|---|---|
| Model Number | PMT-12V200W2BR | PMT-24V200W2BR |
PMT-36V200W2BR |
PMT-48V200W2BR |
| Overvoltage |
13.2 V - 17.4 V SELV Output, Latch Mode |
26.4V - 33.6 V |
39.6 V - 48.6 V SELV Output, Latch Mode |
52.8 V - 64.8 V SELV Output, Latch Mode |
| Overload / Overcurrent | 110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) | |||
| Over Temperature | Latch Mode | |||
| Short Circuit | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
|||
| Protection Against Shock | Class I with PE*⁴ connection | |||
| *4 PE: Primary Earth | ||||
| RELIABILITY DATA | ||||
|---|---|---|---|---|
| Model Number | PMT-12V200W2BR | PMT-24V200W2BR |
PMT-36V200W2BR |
PMT-48V200W2BR |
| MTBF | > 700,000 hrs as per Telcordia SR-332 I/P: 230 Vac, O/P: 100% Load, Ta: 25°C) |
|||
| Expected Cap Life Time | 10 years (230 Vac, 50% load @ 40°C) | |||
| SAFETY STANDARDS/DIRECTIVES | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Model Number | PMT-12V200W2BR | PMT-24V200W2BR | PMT-36V200W2BR | PMT-48V200W2BR | ||||||
| Safety Entry Low Voltage | SELV | |||||||||
| Electrical Safety | TUV Bauart | EN 62368-1,EN 60335-1, EN 61558-1/-2-16 | ||||||||
| cULus | UL 62368-1, and CAN/CSA C22.2 No. 62368-1 | |||||||||
| CB scheme | IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16 | |||||||||
| KC | K 60950-1 (12 & 24 V model) | |||||||||
| EAC | TP TC 004/2011 | |||||||||
| BSMI | CNS 14336-1 | |||||||||
| BIS | IS 13252 (Part 1) | |||||||||
| CCC | GB 4943.1 | |||||||||
| CE | In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU This power supply does not comply with the harmonic current emission requirements specified in BS EN/EN61000-3-2. Please ensure it is not used in applications where compliance with this standard is required |
|||||||||
| UKCA | In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016 | |||||||||
| Galvanic Isolation | Input to Output | 4.0 kVac | ||||||||
| Input to Ground | 2.0 kVac | |||||||||
| Output to Ground | 1.25 kVac | |||||||||
| EMC | ||||
|---|---|---|---|---|
| Emissions (CE & RE) | CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR 32 Compliance to EN/BS EN 55014-1, FCC Title 47, EN/BS EN 61000-6-3 : Class B |
|||
| Immunity | EN/BS EN 55035, KN35, EN/BS EN 61000-6-2 & Compliance to EN/BS EN 55014-2,EN/BS EN 61000-6-1 | |||
| Electrostatic Discharge | IEC 61000-4-2 |
Level 4 Criteria A¹⁾ |
||
| Radiated Field | IEC 61000-4-3 |
Level 3 Criteria A¹⁾ |
||
| Electrical Fast Transient / Burst | IEC 61000-4-4 |
Level 3 Criteria A¹⁾ |
||
| Surge | IEC 61000-4-5 |
Level 4 Criteria A¹⁾ |
||
| Conducted | IEC 61000-4-6 | Level 3 Criteria A¹⁾ 150 kHz – 80 MHz, 10 Vrms |
||
| Power Frequency Magnetic Fields | IEC 61000-4-8 | Level 4 Criteria A¹⁾ 30 A/meter |
||
| Voltage Dips and Interruptions | IEC 61000-4-11 | 0% residual; 1 cycle, Criteria B 40% residual; 10 cycle, Criteria C³⁾ 70% residual; 25 cycle, Criteria C³⁾ |
||
| Harmonic Current Emission | IEC/EN/BS EN 61000-3-2 | Class A | ||
| 1) Criteria A: Normal performance within the specification limits 2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test. 3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test) 4) Asymmetrical: Common mode (Line to earth) 5) Symmetrical: Differential mode (Line to line) |
||||
| MODEL NUMBER | INPUT VOLTAGE RANGE | RATED OUTPUT VOLTAGE | RATED OUTPUT CURRENT |
|---|---|---|---|
| PMT-12V200W2BR |
90-132 Vac, 180-264 Vac (Selectable by Switch) |
12Vdc | 17.0 A |
| PMT-24V200W2BR | 24Vdc | 8.8 A | |
| PMT-36V200W2BR | 36Vdc | 5.9 A | |
| PMT-48V200W2BR | 48Vdc | 4.4 A |
Find the Right Model
| Model Number | Input Voltage (Vac) | Output Voltage (Vdc) | Output Current (A) | ||
|---|---|---|---|---|---|
|
PMT-12V200W2BR | 90-132 Vac, 180-264 Vac (50-60 Hz) | 12Vdc | 17.0A | |
|
PMT-24V200W2BR | 90-132 Vac, 180-264 Vac (50-60 Hz) | 24Vdc | 8.8A | |
|
PMT-36V200W2BR | 90-132 Vac, 180-264 Vac (50-60 Hz) | 36Vdc | 5.9A | |
|
PMT-48V200W2BR | 90-132 Vac, 180-264 Vac (50-60 Hz) | 48Vdc | 4.4A |
Need help finding the right product model?