AC/DC Power Supplies

Schaefer C4500A SERIES AC/DC Power Supply

The Schaefer C4500A Series is a high-performance AC/DC power supply for industrial applications, delivering output power of 1600W. This series supports a wide range of DC output voltages from 9Vdc to 400Vdc. Designed for natural convection cooling, the C4500 Series ensures reliable performance in various environments. Mounting options include chassis mount, wall mount, or 19" rack installation when used with a separate 6U subrack. With options for monitoring, parallel/redundant operation, and conformal coating, the C4500 Series is ideal for demanding sectors such as Railway, Utilities, Mining, and Heavy Industry

Features

  • Industrial Grade AC/DC Power Supply
  • Output Power: 1600W
  • AC Input: 1-Phase and 3-Phase Models
  • Wide Range of DC outputs: 9,12,15, 24, 28, 48, 60, 110, 220,400
  • Flexible mounting options via Chassis, Wall or Euro Cassette (19" rackmount via 6U subrack)
  • Natural Convection Cooling (increased airflow via external fan recommended for high power applications)
Specifications
INPUT
Input voltage 1ph 115/230Vac
3ph 200/400/480Vac
See selection table
Units will turn off with under or over input voltage.
No-load input power 3-6W model (series dependant)
Inrush current AC input limited by thermistor
Switch on time 1-2 seconds.
Input Options Option au: Autoranging for 115/230Vac input Option pr: Power OK via relay contacts
OUTPUT
Output voltage Voltage range; 4.5 - 400Vdc See selection table
Output current See selection table.
Ripple & noise 1% + 30mVpp
Line regulation 0.1% (±10%)
Load regulation 0.2% typical, load step 10-90%
Load transient 6% typical, load step 10-90%
Response time 2-3ms typical ±1%
Temperature coefficient 0.02% per °C typical.
Holdup time 10mS at 220VAC typical
Turn on rise time 100mS typical (soft start)
Remote sensing Standard for all series
Efficiency 80%-92% typical
Output Options Option dd: Decoupling Diode for redundant / parallel operation
Option cs: Active Current Sharing
Option h: Remote on/off (inhibit)
Option dr: DC OK via relay contacts
PROTECTION
Overload protection Current limited at 105%–110% of full load.
Overvoltage protection OVP switches off module with automatic return to operation
Protection Options Option i: Inrush Current Limiting
Option sd: Reverse polarity protection for DC input by Series Diode
MTBF 100Khrs to 140Khrs at 40°C acc. to MIL-HDBK-217E (notice 1)
ENVIRONMENTAL
Operating temperature -20°C to +75°C
(optional -40 to 75C)
Load derating Derate 2.5% per °C, from +55°C to 75°C
Cooling H: Heatsink - natural convection
F: Fan - increased airflow recommended
TF: Temperature controlled Fan included See selection table
Environment Options Option c: Extended temperature range to -40°C
Storage temperature -40°C to +85°C
Humidity Up to 95% RH, non-condensing
STANDARDS
EMI standards acc. to EN61000-6-4 class A, optionally class B
Immunity standards acc. to EN61000-6-2
C-Tick AS/NZS CISPR11: 2002 Group1 Class A
Safety / Construction acc. to EN60950-1 / EN50178
Protection category IP20 acc. to EN60529 NEMA or others on request
MECHANICAL
Mounting See technical illustrations
Eurocassette, pluggable module for 19" subrack
Option w: Wall Mounting
Option cha: Chassis Mounting
Dimensions See Technical illustration
Connector H15 acc. to DIN 41612 H15 and high current connectors for I > 50A, or terminals / bolts / bars
Mechanical Options Option ms: Increased Mechanical Strength
Option t: Tropical protection
19" Rack Mounting Options Subrack Height 3U, 5U, 6U
Wiring, Front Panels
Accessories: Fuses, MCBs, Mains on/off switch
Contact Powerbox for rack configuration
Selection Table
INPUT 115VAC ± 20% INPUT 230VAC +15% - 20% INPUT 115 ± 20% 230VAC +15% 20% INPUT 3X200VAC +15%- 20% INPUT 3X400VAC +15% - 20% INPUT 3X480VAC +15% - 20% OUTPUT AMPS COOLING OUTPUT VOLTAGE VOLTAGE ADJUSTMENT
C4561 C4581 C4591 C4561V C4581V C4591V 110 F 9 8-10
C4562 C4582 C4592 C4562V C4582V C4592V 96 F 12 11-13
C4563 C4583 C4593 C4563V C4583V C4593V 80 F 15 14-16
C4564 C4584 C4594 C4564V C4584V C4594V 56 F 24 23-26
C4565 C4585 C4595 C4565V C4585V C4595V 50 F 28 26-30
C4569 C4589 C4599 C4569V C4589V C4599V 30 F 48 45-55
C4566 C4586 C4596 C4566V C4586V C4596V 24 F 60 58-68
C4567 C4587 C4597 C4567V C4587V C4597V 13 F 110 100-130
C4567J C4587J C4597J C4567VJ C4587VJ C4597VJ 8 F 200 190-200
C4568 C4588 C4598 C4568V C4588V C4598V 6.5 F 220 200-250
C4568J C4588J C4598J C4568VJ C4588VJ C4598VJ 4 F 400 380-400
Cooling H: Heatsink - natural convection
F: Fan - increased airflow recommended
TF: Temperature controlled Fan included
See selection table
Model configuration options: Add the options to the model number, eg. C4594-dd-dr-cs
Options for Input, Output, Environmental and Mechanical follow.
19" Rack Mounting Options Subrack Height 3U, 5U, 6U
Wiring, Front Panels
Accessories: Fuses, MCBs, Mains on/off switch
Contact Powerbox for rack configuration
INPUT OPTIONS
Option “i” (inrush current limiting): A thermistor is connected in series with the input lines which changes its resistance from high to low when it gets hot. It does not reduce the current surge if the input power is interrupted for a short period of time not allowing the thermistor to cool down. Thermistors are fitted as standard to all mains input models except for 1-phase input of models > 2.5kW. Thermistors are available up to 45A. For higher input current an electronic inrush current limitation can be offered.
Option “ie” electronic inrush current limiting An electronic circuit limits the inrush current.
Option “sd” (series diode): A series diode protects the module against input voltage of wrong polarity (additional power losses).
Option “ad” (anti-parallel diode): To avoid the power losses of a series diode a diode is provided with opposite polarity in parallel to the input blowing an internal or external fuse if the module is connected to a supply with wrong polarity.
Option “au” (auto-ranging) For standard dual AC input models the range of 115/230Vac is to be selected by connecting the input line to different pins on the connector. With auto-ranging the unit senses the input voltage and provides automatically the correct connection.
Option “p” (power fail): A signal (logic or relay) is given if the input voltage (AC or DC) drops below the specified limit. In AC input units we sense the rectified input voltage so that a power fail alarm will not be triggered if at light loads mains power returns before the input capacitors are substantially discharged.
Option “r” (relay): A relay instead of a logic signal is provided for failure indication.
OUTPUT OPTIONS
Option “dd” (decoupling diode): For redundant operation the outputs of two or more units are paralleled behind de-coupling diodes so that an internal fault of one module does not affect the operation of the others. These diodes cause power losses.
Option “cs” (active current sharing): An additional control circuit provides active current sharing via an interconnecting wire between converters that operate in parallel. Active current sharing should be used for multi-output units operating in parallel.
Option “csi” (current sharing interrupt): Option "csi" will effect the removal of the "cs" signal. Should there be an instance where a unit is not supplying the load, then the effect of its "cs" signal is removed, and the load voltage is unaffected by this condition.
Option “h1” (inhibit): A terminal connected to the negative input line also shuts off the converter. This can also be used in conjunction with a thermal trip which shuts the unit down.
Option “h2” (inhibit): Operation of the unit is inhibited if a voltage signal (5V/10mA) is applied in reference to the negative line of the (main) output.
Option “rco” (reducing current limiting at over temperature) A circuit reduces the current limiting level at higher temperature (to be specified).
Option “d” (DC-ok, one output): A logic signal is given if the output voltage (main output in multi-output systems) is below the specified limit.
Option “m” (DC-ok, all outputs): In multi-output systems a logic signal is provided if the voltage of any output is below the specified limit.
Option “ac” (AC ok) A logic signal connected to relay contacts is given if the output voltage of an inverter is below the specified limit.
Option "y" (sys-reset): This logic signal is a combination of power fail and DC-ok as specified for VME systems.
Option "r" (relay): A relay instead of a logic signal is provided for failure indication.
ENVIRONMENTAL OPTIONS
Option "t" (tropical protection):The unit is given additional protection by a heavy coat of varnish on the printed circuit board(s) and components.
Option "c" (extended temperature range):The circuit is designed and tested for operation at an ambient temperature as low as –40 °C.
Option "ms" (increased mechanical strength): Screws are secured by Locktite and heavy components are fastened by ties and/or glue. Modules with the "ms" option meet the standard EN61373 regarding shock and vibration.
MECHANICAL OPTIONS
Standard mounting "Eurocassette" pluggable module for 19" sub-racks 8
Option "w" (wall mounting): Module is screwed against a mounting plate for installation in a cabinet. The load connections are typically a terminal block.
Option "cha" (chassis mount) Module is designed for installation to a structure or within cabinet. Screw type connectors are supplied with the module.
Option "din" (DIN rail mount) Module is designed for DIN rail mounting to a structure or within Cabinet. Screw type connectors are supplied with the module.
Technical Illustrations
Downloads
Schaefer_cb4500-AC-DC-PS-BatteryChargers-DC-DC-Converters.pdf
INPUT
Input voltage 1ph 115/230Vac
3ph 200/400/480Vac
See selection table
Units will turn off with under or over input voltage.
No-load input power 3-6W model (series dependant)
Inrush current AC input limited by thermistor
Switch on time 1-2 seconds.
Input Options Option au: Autoranging for 115/230Vac input Option pr: Power OK via relay contacts
OUTPUT
Output voltage Voltage range; 4.5 - 400Vdc See selection table
Output current See selection table.
Ripple & noise 1% + 30mVpp
Line regulation 0.1% (±10%)
Load regulation 0.2% typical, load step 10-90%
Load transient 6% typical, load step 10-90%
Response time 2-3ms typical ±1%
Temperature coefficient 0.02% per °C typical.
Holdup time 10mS at 220VAC typical
Turn on rise time 100mS typical (soft start)
Remote sensing Standard for all series
Efficiency 80%-92% typical
Output Options Option dd: Decoupling Diode for redundant / parallel operation
Option cs: Active Current Sharing
Option h: Remote on/off (inhibit)
Option dr: DC OK via relay contacts
PROTECTION
Overload protection Current limited at 105%–110% of full load.
Overvoltage protection OVP switches off module with automatic return to operation
Protection Options Option i: Inrush Current Limiting
Option sd: Reverse polarity protection for DC input by Series Diode
MTBF 100Khrs to 140Khrs at 40°C acc. to MIL-HDBK-217E (notice 1)
ENVIRONMENTAL
Operating temperature -20°C to +75°C
(optional -40 to 75C)
Load derating Derate 2.5% per °C, from +55°C to 75°C
Cooling H: Heatsink - natural convection
F: Fan - increased airflow recommended
TF: Temperature controlled Fan included See selection table
Environment Options Option c: Extended temperature range to -40°C
Storage temperature -40°C to +85°C
Humidity Up to 95% RH, non-condensing
STANDARDS
EMI standards acc. to EN61000-6-4 class A, optionally class B
Immunity standards acc. to EN61000-6-2
C-Tick AS/NZS CISPR11: 2002 Group1 Class A
Safety / Construction acc. to EN60950-1 / EN50178
Protection category IP20 acc. to EN60529 NEMA or others on request
MECHANICAL
Mounting See technical illustrations
Eurocassette, pluggable module for 19" subrack
Option w: Wall Mounting
Option cha: Chassis Mounting
Dimensions See Technical illustration
Connector H15 acc. to DIN 41612 H15 and high current connectors for I > 50A, or terminals / bolts / bars
Mechanical Options Option ms: Increased Mechanical Strength
Option t: Tropical protection
19" Rack Mounting Options Subrack Height 3U, 5U, 6U
Wiring, Front Panels
Accessories: Fuses, MCBs, Mains on/off switch
Contact Powerbox for rack configuration
INPUT 115VAC ± 20% INPUT 230VAC +15% - 20% INPUT 115 ± 20% 230VAC +15% 20% INPUT 3X200VAC +15%- 20% INPUT 3X400VAC +15% - 20% INPUT 3X480VAC +15% - 20% OUTPUT AMPS COOLING OUTPUT VOLTAGE VOLTAGE ADJUSTMENT
C4561 C4581 C4591 C4561V C4581V C4591V 110 F 9 8-10
C4562 C4582 C4592 C4562V C4582V C4592V 96 F 12 11-13
C4563 C4583 C4593 C4563V C4583V C4593V 80 F 15 14-16
C4564 C4584 C4594 C4564V C4584V C4594V 56 F 24 23-26
C4565 C4585 C4595 C4565V C4585V C4595V 50 F 28 26-30
C4569 C4589 C4599 C4569V C4589V C4599V 30 F 48 45-55
C4566 C4586 C4596 C4566V C4586V C4596V 24 F 60 58-68
C4567 C4587 C4597 C4567V C4587V C4597V 13 F 110 100-130
C4567J C4587J C4597J C4567VJ C4587VJ C4597VJ 8 F 200 190-200
C4568 C4588 C4598 C4568V C4588V C4598V 6.5 F 220 200-250
C4568J C4588J C4598J C4568VJ C4588VJ C4598VJ 4 F 400 380-400
Cooling H: Heatsink - natural convection
F: Fan - increased airflow recommended
TF: Temperature controlled Fan included
See selection table
Model configuration options: Add the options to the model number, eg. C4594-dd-dr-cs
Options for Input, Output, Environmental and Mechanical follow.
19" Rack Mounting Options Subrack Height 3U, 5U, 6U
Wiring, Front Panels
Accessories: Fuses, MCBs, Mains on/off switch
Contact Powerbox for rack configuration
INPUT OPTIONS
Option “i” (inrush current limiting): A thermistor is connected in series with the input lines which changes its resistance from high to low when it gets hot. It does not reduce the current surge if the input power is interrupted for a short period of time not allowing the thermistor to cool down. Thermistors are fitted as standard to all mains input models except for 1-phase input of models > 2.5kW. Thermistors are available up to 45A. For higher input current an electronic inrush current limitation can be offered.
Option “ie” electronic inrush current limiting An electronic circuit limits the inrush current.
Option “sd” (series diode): A series diode protects the module against input voltage of wrong polarity (additional power losses).
Option “ad” (anti-parallel diode): To avoid the power losses of a series diode a diode is provided with opposite polarity in parallel to the input blowing an internal or external fuse if the module is connected to a supply with wrong polarity.
Option “au” (auto-ranging) For standard dual AC input models the range of 115/230Vac is to be selected by connecting the input line to different pins on the connector. With auto-ranging the unit senses the input voltage and provides automatically the correct connection.
Option “p” (power fail): A signal (logic or relay) is given if the input voltage (AC or DC) drops below the specified limit. In AC input units we sense the rectified input voltage so that a power fail alarm will not be triggered if at light loads mains power returns before the input capacitors are substantially discharged.
Option “r” (relay): A relay instead of a logic signal is provided for failure indication.
OUTPUT OPTIONS
Option “dd” (decoupling diode): For redundant operation the outputs of two or more units are paralleled behind de-coupling diodes so that an internal fault of one module does not affect the operation of the others. These diodes cause power losses.
Option “cs” (active current sharing): An additional control circuit provides active current sharing via an interconnecting wire between converters that operate in parallel. Active current sharing should be used for multi-output units operating in parallel.
Option “csi” (current sharing interrupt): Option "csi" will effect the removal of the "cs" signal. Should there be an instance where a unit is not supplying the load, then the effect of its "cs" signal is removed, and the load voltage is unaffected by this condition.
Option “h1” (inhibit): A terminal connected to the negative input line also shuts off the converter. This can also be used in conjunction with a thermal trip which shuts the unit down.
Option “h2” (inhibit): Operation of the unit is inhibited if a voltage signal (5V/10mA) is applied in reference to the negative line of the (main) output.
Option “rco” (reducing current limiting at over temperature) A circuit reduces the current limiting level at higher temperature (to be specified).
Option “d” (DC-ok, one output): A logic signal is given if the output voltage (main output in multi-output systems) is below the specified limit.
Option “m” (DC-ok, all outputs): In multi-output systems a logic signal is provided if the voltage of any output is below the specified limit.
Option “ac” (AC ok) A logic signal connected to relay contacts is given if the output voltage of an inverter is below the specified limit.
Option "y" (sys-reset): This logic signal is a combination of power fail and DC-ok as specified for VME systems.
Option "r" (relay): A relay instead of a logic signal is provided for failure indication.
ENVIRONMENTAL OPTIONS
Option "t" (tropical protection):The unit is given additional protection by a heavy coat of varnish on the printed circuit board(s) and components.
Option "c" (extended temperature range):The circuit is designed and tested for operation at an ambient temperature as low as –40 °C.
Option "ms" (increased mechanical strength): Screws are secured by Locktite and heavy components are fastened by ties and/or glue. Modules with the "ms" option meet the standard EN61373 regarding shock and vibration.
MECHANICAL OPTIONS
Standard mounting "Eurocassette" pluggable module for 19" sub-racks 8
Option "w" (wall mounting): Module is screwed against a mounting plate for installation in a cabinet. The load connections are typically a terminal block.
Option "cha" (chassis mount) Module is designed for installation to a structure or within cabinet. Screw type connectors are supplied with the module.
Option "din" (DIN rail mount) Module is designed for DIN rail mounting to a structure or within Cabinet. Screw type connectors are supplied with the module.
Schaefer_cb4500-AC-DC-PS-BatteryChargers-DC-DC-Converters.pdf

Find the Right Model

Model Number Input Voltage (Vac) Output Voltage (Vdc) Output Current (A)
product variant C4561 115Vac ± 20 % 50/60Hz 9Vdc (Adj. 8 - 10Vdc) 110A
product variant C4562 115Vac ± 20 % 50/60Hz 12Vdc (Adj. 11 - 13Vdc) 96A
product variant C4563 115Vac ± 20 % 50/60Hz 15Vdc (Adj. 14 - 16Vdc) 80A
product variant C4564 115Vac ± 20 % 50/60Hz 24Vdc (Adj. 23 - 26Vdc) 56A
product variant C4565 115Vac ± 20 % 50/60Hz 28Vdc (Adj. 26 - 30Vdc) 50A
product variant C4569 115Vac ± 20 % 50/60Hz 48Vdc (Adj. 45 - 55Vdc) 30A
product variant C4566 115Vac ± 20 % 50/60Hz 60Vdc (Adj. 58 - 68Vdc) 24A
product variant C4567 115Vac ± 20 % 50/60Hz 110Vdc (Adj. 100 - 130Vdc) 13A
product variant C4567J 115Vac ± 20 % 50/60Hz 200Vdc(Adj. 190 - 200Vdc) 8A
product variant C4568 115Vac ± 20 % 50/60Hz 220Vdc (Adj. 200 - 250Vdc) 6.5A
product variant C4568J 115Vac ± 20 % 50/60Hz 400Vdc (Adj. 380 - 400Vdc) 4A
product variant C4581 230Vac +15%/-20% 50/60Hz 9Vdc (Adj. 8 - 10Vdc) 110A
product variant C4582 230Vac +15%/-20% 50/60Hz 12Vdc (Adj. 11 - 13Vdc) 96A
product variant C4583 230Vac +15%/-20% 50/60Hz 15Vdc (Adj. 14 - 16Vdc) 80A
product variant C4584 230Vac +15%/-20% 50/60Hz 24Vdc (Adj. 23 - 26Vdc) 56A
product variant C4585 230Vac +15%/-20% 50/60Hz 28Vdc (Adj. 26 - 30Vdc) 50A
product variant C4589 230Vac +15%/-20% 50/60Hz 48Vdc (Adj. 45 - 55Vdc) 30A
product variant C4586 230Vac +15%/-20% 50/60Hz 60Vdc (Adj. 58 - 68Vdc) 24A
product variant C4587 230Vac +15%/-20% 50/60Hz 110Vdc (Adj. 100 - 130Vdc) 13A
product variant C4587J 230Vac +15%/-20% 50/60Hz 200Vdc(Adj. 190 - 200Vdc) 8A
product variant C4588 230Vac +15%/-20% 50/60Hz 220Vdc (Adj. 200 - 250Vdc) 6.5A
product variant C4588J 230Vac +15%/-20% 50/60Hz 400Vdc (Adj. 380 - 400Vdc) 4A
product variant C4591 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 9Vdc (Adj. 8 - 10Vdc) 110A
product variant C4592 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 12Vdc (Adj. 11 - 13Vdc) 96A
product variant C4593 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 15Vdc (Adj. 14 - 16Vdc) 80A
product variant C4594 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 24Vdc (Adj. 23 - 26Vdc) 56A
product variant C4595 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 28Vdc (Adj. 26 - 30Vdc) 50A
product variant C4599 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 48Vdc (Adj. 45 - 55Vdc) 30A
product variant C4596 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 60Vdc (Adj. 58 - 68Vdc) 24A
product variant C4597 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 110Vdc (Adj. 100 - 130Vdc) 13A
product variant C4597J 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 200Vdc(Adj. 190 - 200Vdc) 8A
product variant C4598 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 220Vdc (Adj. 200 - 250Vdc) 6.5A
product variant C4598J 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 400Vdc (Adj. 380 - 400Vdc) 4A
product variant C4561V 3 x 200Vac +15%/-20% 50/60Hz 9Vdc (Adj. 8 - 10Vdc) 110A
product variant C4562V 3 x 200Vac +15%/-20% 50/60Hz 12Vdc (Adj. 11 - 13Vdc) 96A
product variant C4563V 3 x 200Vac +15%/-20% 50/60Hz 15Vdc (Adj. 14 - 16Vdc) 80A
product variant C4564V 3 x 200Vac +15%/-20% 50/60Hz 24Vdc (Adj. 23 - 26Vdc) 56A
product variant C4565V 3 x 200Vac +15%/-20% 50/60Hz 28Vdc (Adj. 26 - 30Vdc) 50A
product variant C4569V 3 x 200Vac +15%/-20% 50/60Hz 48Vdc (Adj. 45 - 55Vdc) 30A
product variant C4566V 3 x 200Vac +15%/-20% 50/60Hz 60Vdc (Adj. 58 - 68Vdc) 24A
product variant C4567V 3 x 200Vac +15%/-20% 50/60Hz 110Vdc (Adj. 100 - 130Vdc) 13A
product variant C4567VJ 3 x 200Vac +15%/-20% 50/60Hz 200Vdc(Adj. 190 - 200Vdc) 8A
product variant C4568V 3 x 200Vac +15%/-20% 50/60Hz 220Vdc (Adj. 200 - 250Vdc) 6.5A
product variant C4568VJ 3 x 200Vac +15%/-20% 50/60Hz 400Vdc (Adj. 380 - 400Vdc) 4A
product variant C4581V 3 x 400Vac +15%/-20% 50/60Hz 9Vdc (Adj. 8 - 10Vdc) 110A
product variant C4582V 3 x 400Vac +15%/-20% 50/60Hz 12Vdc (Adj. 11 - 13Vdc) 96A
product variant C4583V 3 x 400Vac +15%/-20% 50/60Hz 15Vdc (Adj. 14 - 16Vdc) 80A
product variant C4584V 3 x 400Vac +15%/-20% 50/60Hz 24Vdc (Adj. 23 - 26Vdc) 56A
product variant C4585V 3 x 400Vac +15%/-20% 50/60Hz 28Vdc (Adj. 26 - 30Vdc) 50A
product variant C4589V 3 x 400Vac +15%/-20% 50/60Hz 48Vdc (Adj. 45 - 55Vdc) 30A
product variant C4586V 3 x 400Vac +15%/-20% 50/60Hz 60Vdc (Adj. 58 - 68Vdc) 24A
product variant C4587V 3 x 400Vac +15%/-20% 50/60Hz 110Vdc (Adj. 100 - 130Vdc) 13A
product variant C4587VJ 3 x 400Vac +15%/-20% 50/60Hz 200Vdc(Adj. 190 - 200Vdc) 8A
product variant C4588V 3 x 400Vac +15%/-20% 50/60Hz 220Vdc (Adj. 200 - 250Vdc) 6.5A
product variant C4588VJ 3 x 400Vac +15%/-20% 50/60Hz 400Vdc (Adj. 380 - 400Vdc) 4A
product variant C4591V 3 x 480Vac +10%/-15% 50/60Hz 9Vdc (Adj. 8 - 10Vdc) 110A
product variant C4592V 3 x 480Vac +10%/-15% 50/60Hz 12Vdc (Adj. 11 - 13Vdc) 96A
product variant C4593V 3 x 480Vac +10%/-15% 50/60Hz 15Vdc (Adj. 14 - 16Vdc) 80A
product variant C4594V 3 x 480Vac +10%/-15% 50/60Hz 24Vdc (Adj. 23 - 26Vdc) 56A
product variant C4595V 3 x 480Vac +10%/-15% 50/60Hz 28Vdc (Adj. 26 - 30Vdc) 50A
product variant C4599V 3 x 480Vac +10%/-15% 50/60Hz 48Vdc (Adj. 45 - 55Vdc) 30A
product variant C4596V 3 x 480Vac +10%/-15% 50/60Hz 60Vdc (Adj. 58 - 68Vdc) 24A
product variant C4597V 3 x 480Vac +10%/-15% 50/60Hz 110Vdc (Adj. 100 - 130Vdc) 13A
product variant C4597VJ 3 x 480Vac +10%/-15% 50/60Hz 200Vdc(Adj. 190 - 200Vdc) 8A
product variant C4598V 3 x 480Vac +10%/-15% 50/60Hz 220Vdc (Adj. 200 - 250Vdc) 6.5A
product variant C4598VJ 3 x 480Vac +10%/-15% 50/60Hz 400Vdc (Adj. 380 - 400Vdc) 4A

Need help finding the right product model?