AC/DC Power Supplies

Schaefer C3800A SERIES AC/DC Power Supply

The Schaefer C3800A Series is a high-performance AC/DC power supply for industrial applications, delivering an output power of 2.5kW. This series supports a range of DC output voltages from 12Vdc to 400Vdc. Designed for natural convection cooling, the C3800A Series ensures reliable performance in various demanding environments. Mounting options include wall mount or 19" rack installation when used with a separate 6U subrack. With options for monitoring, parallel/redundant operation, and conformal coating, the C3800A Series is well-suited for sectors such as Railway, Utilities, Mining, and Heavy Industry.

Features

  • Industrial Grade 2500W AC/DC Power Supply
  • AC Input: 1-Phase and 3-Phase Models
  • Wide Range of DC outputs: 12,15, 24, 28, 48, 60, 110, 220,400
  • Flexible mounting options via Wall or Euro Cassette (19" rackmount via 6U subrack)
  • Natural Convection Cooling (increased airflow via external fan recommended for high power applications)
Specifications
INPUT
Input voltage 1ph 115/230Vac
3ph 200/400/480Vac
See selection table
Units will turn off with under or over input voltage.
No-load input power 3-6W model (series dependant)
Inrush current AC input limited by thermistor
Switch on time 1-2 seconds.
Input Options Option au: Autoranging for 115/230Vac input
Option pr: Power OK via relay contacts
OUTPUT
Output voltage Voltage Range: 12V - 400Vdc
See selection table
Output current See selection table.
Ripple & noise 1% + 30mVpp
Line regulation 0.1% (±10%)
Load regulation 0.2% typical, load step 10-90%
Load transient 6% typical, load step 10-90%
Response time 2-3ms typical ±1%
Temperature coefficient 0.02% per °C typical.
Holdup time 10mS at 220VAC typical
Turn on rise time 100mS typical (soft start)
Remote sensing Standard for all series
Efficiency 80%-92% typical
Output Options Option dd: Decoupling Diode for redundant / parallel operation
Option cs: Active Current Sharing
Option h: Remote on/off (inhibit)
Option dr: DC OK via relay contacts
PROTECTION
Overload protection Current limited at 105%–110% of full load.
Overvoltage protection OVP switches off module with automatic return to operation
Protection Options Option i: Inrush Current Limiting
Option sd: Reverse polarity protection for DC input by Series Diode
MTBF 100Khrs to 140Khrs at 40°C acc. to MIL-HDBK-217E (notice 1)
ENVIRONMENTAL
Operating temperature -20°C to +75°C
(optional -40 to 75C)
Load derating Derate 2.5% per °C, from +55°C to 75°C
Cooling H: Heatsink - natural convection
F: Fan - increased airflow recommended
TF: Temperature controlled Fan included See selection table
Environment Options Option c: Extended temperature range to -40°C
Storage temperature -40°C to +85°C
Humidity Up to 95% RH, non-condensing
STANDARDS
EMI standards acc. to EN61000-6-4 class A, optionally class B
Immunity standards acc. to EN61000-6-2
C-Tick AS/NZS CISPR11: 2002 Group1 Class A
Safety / Construction acc. to EN60950-1 / EN50178
Protection category IP20 acc. to EN60529 NEMA or others on request
MECHANICAL
Mounting See technical illustrations
Eurocassette, pluggable module for 19" subrack
Option w: Wall Mounting
Option cha: Chassis Mounting
Dimensions See Technical illustration
Connector H15 acc. to DIN 41612 H15
and high current connectors for I > 50A,
or terminals / bolts / bars
Mechanical Options Option ms: Increased Mechanical Strength
Option t: Tropical protection
19" Rack Mounting Options Subrack Height 3U, 5U, 6U
Wiring, Front Panels
Accessories: Fuses, MCBs, Mains on/off switch
Contact Powerbox for rack configuration
Selection Table
INPUT 115VAC ±20% INPUT 230VAC +15% – 20% INPUT 115 ± 20 % / 230VAC+15% – 20% INPUT 3X200VAC +15% –20% INPUT 3X400VAC +15% – 20% INPUT 3X480VAC +15% –20% OUTPUT AMPS COOLING OUTPUT VOLTAGE VOLTAGE ADJUSTMENT RANGE
C3862 C3882 C3892 C3862V C3882V C3892V 160 F 12 11 – 13
C3863 C3883 C3893 C3863V C3883V C3893V 130 F 15 14 – 16
C3864 C3884 C3894 C3864V C3884V C3894V 100 H 24 23 – 26
C3665 C3885 C3895 C3865V C3885V C3895V 85 H 28 26 – 30
C3869 C3889 C3899 C3869V C3889V C3899V 45 H 48 45 – 55
C3866 C3886 C3896 C3866V C3886V C3896V 36 H 60 58 – 68
C3867 C3887 C3897 C3867V C3887V C3897V 20 H 110 100 – 130
C3867J C3887J C3897J C3867VJ C3887VJ C3897VJ 12 H 200 190 – 200
C3868 C3888 C3898 C3868V C3888V C3898V 10 H 220 200 – 250
C3868J C3888J C3898J C3868VJ C3888VJ C3898VJ 6 H 400 380 – 400
Cooling H: Heatsink - natural convection
F: Fan - increased airflow recommended
TF: Temperature controlled Fan included
See selection table
Model configuration options: Add the options to the model number, eg. C3862-dd-dr-cs Options for Input, Output, Environmental and Mechanical follow.
19" Rack Mounting Options Subrack Height 3U, 5U, 6U
Wiring, Front Panels
Accessories: Fuses, MCBs, Mains on/off switch
Contact Powerbox for rack configuration
INPUT OPTIONS
Option “i” (inrush current limiting): A thermistor is connected in series with the input lines which changes its resistance from high to low when it gets hot. It does not reduce the current surge if the input power is interrupted for a short period of time not allowing the thermistor to cool down. Thermistors are fitted as standard to all mains input models except for 1-phase input of models > 2.5kW. Thermistors are available up to 45A. For higher input current an electronic inrush current limitation can be offered.
Option “ie” electronic inrush current limiting An electronic circuit limits the inrush current.
Option “sd” (series diode): A series diode protects the module against input voltage of wrong polarity (additional power losses).
Option “ad” (anti-parallel diode): To avoid the power losses of a series diode a diode is provided with opposite polarity in parallel to the input blowing an internal or external fuse if the module is connected to a supply with wrong polarity.
Option “au” (auto-ranging) For standard dual AC input models the range of 115/230Vac is to be selected by connecting the input line to different pins on the connector. With auto-ranging the unit senses the input voltage and provides automatically the correct connection.
Option “p” (power fail): A signal (logic or relay) is given if the input voltage (AC or DC) drops below the specified limit. In AC input units we sense the rectified input voltage so that a power fail alarm will not be triggered if at light loads mains power returns before the input capacitors are substantially discharged.
Option “r” (relay): A relay instead of a logic signal is provided for failure indication.
OUTPUT OPTIONS
Option “dd” (decoupling diode): For redundant operation the outputs of two or more units are paralleled behind de-coupling diodes so that an internal fault of one module does not affect the operation of the others. These diodes cause power losses.
Option “cs” (active current sharing): An additional control circuit provides active current sharing via an interconnecting wire between converters that operate in parallel. Active current sharing should be used for multi-output units operating in parallel.
Option “csi” (current sharing interrupt): Option "csi" will effect the removal of the "cs" signal. Should there be an instance where a unit is not supplying the load, then the effect of its "cs" signal is removed, and the load voltage is unaffected by this condition.
Option “h1” (inhibit): A terminal connected to the negative input line also shuts off the converter. This can also be used in conjunction with a thermal trip which shuts the unit down.
Option “h2” (inhibit): Operation of the unit is inhibited if a voltage signal (5V/10mA) is applied in reference to the negative line of the (main) output.
Option “rco” (reducing current limiting at over temperature) A circuit reduces the current limiting level at higher temperature (to be specified).
Option “d” (DC-ok, one output): A logic signal is given if the output voltage (main output in multi-output systems) is below the specified limit.
Option “m” (DC-ok, all outputs): In multi-output systems a logic signal is provided if the voltage of any output is below the specified limit.
Option “ac” (AC ok) A logic signal connected to relay contacts is given if the output voltage of an inverter is below the specified limit.
Option "y" (sys-reset): This logic signal is a combination of power fail and DC-ok as specified for VME systems.
Option "r" (relay): A relay instead of a logic signal is provided for failure indication.
environmental options
Option "t" (tropical protection):The unit is given additional protection by a heavy coat of varnish on the printed circuit board(s) and components.
Option "c" (extended temperature range):The circuit is designed and tested for operation at an ambient temperature as low as –40 °C.
Option "ms" (increased mechanical strength): Screws are secured by Locktite and heavy components are fastened by ties and/or glue. Modules with the "ms" option meet the standard EN61373 regarding shock and vibration.
mechanical options
Standard mounting "Eurocassette" pluggable module for 19" sub-racks 8
Option "w" (wall mounting): Module is screwed against a mounting plate for installation in a cabinet. The load connections are typically a terminal block.
Option "cha" (chassis mount) Module is designed for installation to a structure or within cabinet. Screw type connectors are supplied with the module.
Option "din" (DIN rail mount) Module is designed for DIN rail mounting to a structure or within Cabinet. Screw type connectors are supplied with the module.
Technical Illustrations
Downloads
Schaefer_cb3800-AC-DC-PS-BatteryChargers-DC-DC-Converters.pdf
INPUT
Input voltage 1ph 115/230Vac
3ph 200/400/480Vac
See selection table
Units will turn off with under or over input voltage.
No-load input power 3-6W model (series dependant)
Inrush current AC input limited by thermistor
Switch on time 1-2 seconds.
Input Options Option au: Autoranging for 115/230Vac input
Option pr: Power OK via relay contacts
OUTPUT
Output voltage Voltage Range: 12V - 400Vdc
See selection table
Output current See selection table.
Ripple & noise 1% + 30mVpp
Line regulation 0.1% (±10%)
Load regulation 0.2% typical, load step 10-90%
Load transient 6% typical, load step 10-90%
Response time 2-3ms typical ±1%
Temperature coefficient 0.02% per °C typical.
Holdup time 10mS at 220VAC typical
Turn on rise time 100mS typical (soft start)
Remote sensing Standard for all series
Efficiency 80%-92% typical
Output Options Option dd: Decoupling Diode for redundant / parallel operation
Option cs: Active Current Sharing
Option h: Remote on/off (inhibit)
Option dr: DC OK via relay contacts
PROTECTION
Overload protection Current limited at 105%–110% of full load.
Overvoltage protection OVP switches off module with automatic return to operation
Protection Options Option i: Inrush Current Limiting
Option sd: Reverse polarity protection for DC input by Series Diode
MTBF 100Khrs to 140Khrs at 40°C acc. to MIL-HDBK-217E (notice 1)
ENVIRONMENTAL
Operating temperature -20°C to +75°C
(optional -40 to 75C)
Load derating Derate 2.5% per °C, from +55°C to 75°C
Cooling H: Heatsink - natural convection
F: Fan - increased airflow recommended
TF: Temperature controlled Fan included See selection table
Environment Options Option c: Extended temperature range to -40°C
Storage temperature -40°C to +85°C
Humidity Up to 95% RH, non-condensing
STANDARDS
EMI standards acc. to EN61000-6-4 class A, optionally class B
Immunity standards acc. to EN61000-6-2
C-Tick AS/NZS CISPR11: 2002 Group1 Class A
Safety / Construction acc. to EN60950-1 / EN50178
Protection category IP20 acc. to EN60529 NEMA or others on request
MECHANICAL
Mounting See technical illustrations
Eurocassette, pluggable module for 19" subrack
Option w: Wall Mounting
Option cha: Chassis Mounting
Dimensions See Technical illustration
Connector H15 acc. to DIN 41612 H15
and high current connectors for I > 50A,
or terminals / bolts / bars
Mechanical Options Option ms: Increased Mechanical Strength
Option t: Tropical protection
19" Rack Mounting Options Subrack Height 3U, 5U, 6U
Wiring, Front Panels
Accessories: Fuses, MCBs, Mains on/off switch
Contact Powerbox for rack configuration
INPUT 115VAC ±20% INPUT 230VAC +15% – 20% INPUT 115 ± 20 % / 230VAC+15% – 20% INPUT 3X200VAC +15% –20% INPUT 3X400VAC +15% – 20% INPUT 3X480VAC +15% –20% OUTPUT AMPS COOLING OUTPUT VOLTAGE VOLTAGE ADJUSTMENT RANGE
C3862 C3882 C3892 C3862V C3882V C3892V 160 F 12 11 – 13
C3863 C3883 C3893 C3863V C3883V C3893V 130 F 15 14 – 16
C3864 C3884 C3894 C3864V C3884V C3894V 100 H 24 23 – 26
C3665 C3885 C3895 C3865V C3885V C3895V 85 H 28 26 – 30
C3869 C3889 C3899 C3869V C3889V C3899V 45 H 48 45 – 55
C3866 C3886 C3896 C3866V C3886V C3896V 36 H 60 58 – 68
C3867 C3887 C3897 C3867V C3887V C3897V 20 H 110 100 – 130
C3867J C3887J C3897J C3867VJ C3887VJ C3897VJ 12 H 200 190 – 200
C3868 C3888 C3898 C3868V C3888V C3898V 10 H 220 200 – 250
C3868J C3888J C3898J C3868VJ C3888VJ C3898VJ 6 H 400 380 – 400
Cooling H: Heatsink - natural convection
F: Fan - increased airflow recommended
TF: Temperature controlled Fan included
See selection table
Model configuration options: Add the options to the model number, eg. C3862-dd-dr-cs Options for Input, Output, Environmental and Mechanical follow.
19" Rack Mounting Options Subrack Height 3U, 5U, 6U
Wiring, Front Panels
Accessories: Fuses, MCBs, Mains on/off switch
Contact Powerbox for rack configuration
INPUT OPTIONS
Option “i” (inrush current limiting): A thermistor is connected in series with the input lines which changes its resistance from high to low when it gets hot. It does not reduce the current surge if the input power is interrupted for a short period of time not allowing the thermistor to cool down. Thermistors are fitted as standard to all mains input models except for 1-phase input of models > 2.5kW. Thermistors are available up to 45A. For higher input current an electronic inrush current limitation can be offered.
Option “ie” electronic inrush current limiting An electronic circuit limits the inrush current.
Option “sd” (series diode): A series diode protects the module against input voltage of wrong polarity (additional power losses).
Option “ad” (anti-parallel diode): To avoid the power losses of a series diode a diode is provided with opposite polarity in parallel to the input blowing an internal or external fuse if the module is connected to a supply with wrong polarity.
Option “au” (auto-ranging) For standard dual AC input models the range of 115/230Vac is to be selected by connecting the input line to different pins on the connector. With auto-ranging the unit senses the input voltage and provides automatically the correct connection.
Option “p” (power fail): A signal (logic or relay) is given if the input voltage (AC or DC) drops below the specified limit. In AC input units we sense the rectified input voltage so that a power fail alarm will not be triggered if at light loads mains power returns before the input capacitors are substantially discharged.
Option “r” (relay): A relay instead of a logic signal is provided for failure indication.
OUTPUT OPTIONS
Option “dd” (decoupling diode): For redundant operation the outputs of two or more units are paralleled behind de-coupling diodes so that an internal fault of one module does not affect the operation of the others. These diodes cause power losses.
Option “cs” (active current sharing): An additional control circuit provides active current sharing via an interconnecting wire between converters that operate in parallel. Active current sharing should be used for multi-output units operating in parallel.
Option “csi” (current sharing interrupt): Option "csi" will effect the removal of the "cs" signal. Should there be an instance where a unit is not supplying the load, then the effect of its "cs" signal is removed, and the load voltage is unaffected by this condition.
Option “h1” (inhibit): A terminal connected to the negative input line also shuts off the converter. This can also be used in conjunction with a thermal trip which shuts the unit down.
Option “h2” (inhibit): Operation of the unit is inhibited if a voltage signal (5V/10mA) is applied in reference to the negative line of the (main) output.
Option “rco” (reducing current limiting at over temperature) A circuit reduces the current limiting level at higher temperature (to be specified).
Option “d” (DC-ok, one output): A logic signal is given if the output voltage (main output in multi-output systems) is below the specified limit.
Option “m” (DC-ok, all outputs): In multi-output systems a logic signal is provided if the voltage of any output is below the specified limit.
Option “ac” (AC ok) A logic signal connected to relay contacts is given if the output voltage of an inverter is below the specified limit.
Option "y" (sys-reset): This logic signal is a combination of power fail and DC-ok as specified for VME systems.
Option "r" (relay): A relay instead of a logic signal is provided for failure indication.
environmental options
Option "t" (tropical protection):The unit is given additional protection by a heavy coat of varnish on the printed circuit board(s) and components.
Option "c" (extended temperature range):The circuit is designed and tested for operation at an ambient temperature as low as –40 °C.
Option "ms" (increased mechanical strength): Screws are secured by Locktite and heavy components are fastened by ties and/or glue. Modules with the "ms" option meet the standard EN61373 regarding shock and vibration.
mechanical options
Standard mounting "Eurocassette" pluggable module for 19" sub-racks 8
Option "w" (wall mounting): Module is screwed against a mounting plate for installation in a cabinet. The load connections are typically a terminal block.
Option "cha" (chassis mount) Module is designed for installation to a structure or within cabinet. Screw type connectors are supplied with the module.
Option "din" (DIN rail mount) Module is designed for DIN rail mounting to a structure or within Cabinet. Screw type connectors are supplied with the module.
Schaefer_cb3800-AC-DC-PS-BatteryChargers-DC-DC-Converters.pdf

Find the Right Model

Model Number Input Voltage (Vac) Output Voltage (Vdc) Output Current (A)
product variant C3862 115Vac ± 20 % 50/60Hz 12Vdc (Adj. 11 - 13Vdc) 160A
product variant C3863 115Vac ± 20 % 50/60Hz 15Vdc (Adj. 14 - 16Vdc) 130A
product variant C3864 115Vac ± 20 % 50/60Hz 24Vdc (Adj. 23 - 26Vdc) 100A
product variant C3665 115Vac ± 20 % 50/60Hz 28Vdc (Adj. 26 - 30Vdc) 85A
product variant C3869 115Vac ± 20 % 50/60Hz 48Vdc (Adj. 45 - 55Vdc) 45A
product variant C3866 115Vac ± 20 % 50/60Hz 60Vdc (Adj. 58 - 68Vdc) 36A
product variant C3867 115Vac ± 20 % 50/60Hz 110Vdc (Adj. 100 - 130Vdc) 20A
product variant C3867J 115Vac ± 20 % 50/60Hz 200Vdc(Adj. 190 - 200Vdc) 12A
product variant C3868 115Vac ± 20 % 50/60Hz 220Vdc (Adj. 200 - 250Vdc) 10A
product variant C3868J 115Vac ± 20 % 50/60Hz 400Vdc (Adj. 380 - 400Vdc) 6A
product variant C3882 230Vac +15%/-20% 50/60Hz 12Vdc (Adj. 11 - 13Vdc) 160A
product variant C3883 230Vac +15%/-20% 50/60Hz 15Vdc (Adj. 14 - 16Vdc) 130A
product variant C3884 230Vac +15%/-20% 50/60Hz 24Vdc (Adj. 23 - 26Vdc) 100A
product variant C3685 230Vac +15%/-20% 50/60Hz 28Vdc (Adj. 26 - 30Vdc) 85A
product variant C3889 230Vac +15%/-20% 50/60Hz 48Vdc (Adj. 45 - 55Vdc) 45A
product variant C3886 230Vac +15%/-20% 50/60Hz 60Vdc (Adj. 58 - 68Vdc) 36A
product variant C3887 230Vac +15%/-20% 50/60Hz 110Vdc (Adj. 100 - 130Vdc) 20A
product variant C3887J 230Vac +15%/-20% 50/60Hz 200Vdc(Adj. 190 - 200Vdc) 12A
product variant C3888 230Vac +15%/-20% 50/60Hz 220Vdc (Adj. 200 - 250Vdc) 10A
product variant C3888J 230Vac +15%/-20% 50/60Hz 400Vdc (Adj. 380 - 400Vdc) 6A
product variant C3892 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 12Vdc (Adj. 11 - 13Vdc) 160A
product variant C3893 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 15Vdc (Adj. 14 - 16Vdc) 130A
product variant C3894 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 24Vdc (Adj. 23 - 26Vdc) 100A
product variant C3895 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 28Vdc (Adj. 26 - 30Vdc) 85A
product variant C3899 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 48Vdc (Adj. 45 - 55Vdc) 45A
product variant C3896 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 60Vdc (Adj. 58 - 68Vdc) 36A
product variant C3897 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 110Vdc (Adj. 100 - 130Vdc) 20A
product variant C3897J 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 200Vdc(Adj. 190 - 200Vdc) 12A
product variant C3898 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 220Vdc (Adj. 200 - 250Vdc) 10A
product variant C3898J 115Vac ± 20 % 50/60Hz or 230Vac +15%/-20% 50/60Hz 400Vdc (Adj. 380 - 400Vdc) 6A
product variant C3862V 3 x 200Vac +15%/-20% 50/60Hz 12Vdc (Adj. 11 - 13Vdc) 160A
product variant C3863V 3 x 200Vac +15%/-20% 50/60Hz 15Vdc (Adj. 14 - 16Vdc) 130A
product variant C3864V 3 x 200Vac +15%/-20% 50/60Hz 24Vdc (Adj. 23 - 26Vdc) 100A
product variant C3665V 3 x 200Vac +15%/-20% 50/60Hz 28Vdc (Adj. 26 - 30Vdc) 85A
product variant C3869V 3 x 200Vac +15%/-20% 50/60Hz 48Vdc (Adj. 45 - 55Vdc) 45A
product variant C3866V 3 x 200Vac +15%/-20% 50/60Hz 60Vdc (Adj. 58 - 68Vdc) 36A
product variant C3867V 3 x 200Vac +15%/-20% 50/60Hz 110Vdc (Adj. 100 - 130Vdc) 20A
product variant C3867VJ 3 x 200Vac +15%/-20% 50/60Hz 200Vdc(Adj. 190 - 200Vdc) 12A
product variant C3868V 3 x 200Vac +15%/-20% 50/60Hz 220Vdc (Adj. 200 - 250Vdc) 10A
product variant C3868VJ 3 x 200Vac +15%/-20% 50/60Hz 400Vdc (Adj. 380 - 400Vdc) 6A
product variant C3882V 3 x 400Vac +15%/-20% 50/60Hz 12Vdc (Adj. 11 - 13Vdc) 160A
product variant C3883V 3 x 400Vac +15%/-20% 50/60Hz 15Vdc (Adj. 14 - 16Vdc) 130A
product variant C3884V 3 x 400Vac +15%/-20% 50/60Hz 24Vdc (Adj. 23 - 26Vdc) 100A
product variant C3685V 3 x 400Vac +15%/-20% 50/60Hz 28Vdc (Adj. 26 - 30Vdc) 85A
product variant C3889V 3 x 400Vac +15%/-20% 50/60Hz 48Vdc (Adj. 45 - 55Vdc) 45A
product variant C3886V 3 x 400Vac +15%/-20% 50/60Hz 60Vdc (Adj. 58 - 68Vdc) 36A
product variant C3887V 3 x 400Vac +15%/-20% 50/60Hz 110Vdc (Adj. 100 - 130Vdc) 20A
product variant C3887VJ 3 x 400Vac +15%/-20% 50/60Hz 200Vdc(Adj. 190 - 200Vdc) 12A
product variant C3888V 3 x 400Vac +15%/-20% 50/60Hz 220Vdc (Adj. 200 - 250Vdc) 10A
product variant C3888VJ 3 x 400Vac +15%/-20% 50/60Hz 400Vdc (Adj. 380 - 400Vdc) 6A
product variant C3892V 3 x 480Vac +10%/-15% 50/60Hz 12Vdc (Adj. 11 - 13Vdc) 160A
product variant C3893V 3 x 480Vac +10%/-15% 50/60Hz 15Vdc (Adj. 14 - 16Vdc) 130A
product variant C3894V 3 x 480Vac +10%/-15% 50/60Hz 24Vdc (Adj. 23 - 26Vdc) 100A
product variant C3695V 3 x 480Vac +10%/-15% 50/60Hz 28Vdc (Adj. 26 - 30Vdc) 85A
product variant C3899V 3 x 480Vac +10%/-15% 50/60Hz 48Vdc (Adj. 45 - 55Vdc) 45A
product variant C3896V 3 x 480Vac +10%/-15% 50/60Hz 60Vdc (Adj. 58 - 68Vdc) 36A
product variant C3897V 3 x 480Vac +10%/-15% 50/60Hz 110Vdc (Adj. 100 - 130Vdc) 20A
product variant C3897VJ 3 x 480Vac +10%/-15% 50/60Hz 200Vdc(Adj. 190 - 200Vdc) 12A
product variant C3898V 3 x 480Vac +10%/-15% 50/60Hz 220Vdc (Adj. 200 - 250Vdc) 10A
product variant C3898VJ 3 x 480Vac +10%/-15% 50/60Hz 400Vdc (Adj. 380 - 400Vdc) 6A