DC/DC Converters

PRBX DAB Defense Line Series DC/DC Converter

The PRBX DAB Defense Line Series DC/DC Converter is a compact and reliable solution for defense, industrial, and railway applications.

Read More

Features

  • Defense dc converter
  • 24. 48. 72. 110VDC in
  • Several output from 3V3 to 48VDC
  • Input filtering EN55022 & transient protection
  • Reverse polarity protection
  • Parallel or series operations up to several kWs
Specifications
ELECTRICAL DATA
Input voltage See Find The Right Model Table
Input fuse Protects against damages in case of a failure.
Input transient protection Yes
Input reverse polarity A diode placed internally
Parallel/series Possible.
Redundant operation Oring diodes are required to ensure proper N+1 operation (included with optional N+1 bus bar).
Hold-up time Limited hold-up time.
Output current limitation Continously protected against short-circuit.
Thermal considerations Baseplate which should not exceed 100°C.
Thermal protection OTP protection, automatic restart.
Primary inhibit Remote on/off.
Output voltage adj. Yes
Sense lines Enables compensation of voltage drop. V1, total drop <0.5, negative line drop <0.25
Power good Green LED.
Paralleling signal Yes.
Options
Heatsink (H) The unit is built as standard with a aluminum baseplate as described in the mechanical data. The converter can be delivered with a 15mm heatsink
Ruggedized (M) The unit can be ruggedized to meet MIL-STD810E, MIL-STD461E CE102. M opton with 12 and 24Vin will comply with MIL STD 1275A on DAA and DBB only.
-40°C operation (T) The thermal grade of the components are comply with low ambient temperature.
Conformal coating (V) During manufacturing process components and pcb are covered with an acrylic coating to address high level of ambiant humidity application.
ENVIRONMENTAL
Damp heat MIL STD 810 Proc. 507-2
Shock MIL STD 810 Proc. 516.3
Vibrations MIL STD 810 Proc. 514-5
General
Electric strength Input to earth 1500Vrms. Input to output 3000Vrms. Output to earth 500Vrms
Insulation resistance >100Mohms.
STANDARDS
Safety standards Built to meet IEC60950-1, EN60950-1.
Railway application Designed to meet EN50155, EN50121
Electromagnetic immunity
Supply surge EN50155.
Direct transients EN50155
Surges EN61000-4-5.
Electrostatic discharge EN61000-4-2.
Fast transients/burst EN61000-4-4
Technical Illustrations
Downloads
DAA_DAB_DAC_Series_Datasheet.pdf
PRBX_Part_number_configurator.xlsm
ELECTRICAL DATA
Input voltage See Find The Right Model Table
Input fuse Protects against damages in case of a failure.
Input transient protection Yes
Input reverse polarity A diode placed internally
Parallel/series Possible.
Redundant operation Oring diodes are required to ensure proper N+1 operation (included with optional N+1 bus bar).
Hold-up time Limited hold-up time.
Output current limitation Continously protected against short-circuit.
Thermal considerations Baseplate which should not exceed 100°C.
Thermal protection OTP protection, automatic restart.
Primary inhibit Remote on/off.
Output voltage adj. Yes
Sense lines Enables compensation of voltage drop. V1, total drop <0.5, negative line drop <0.25
Power good Green LED.
Paralleling signal Yes.
Options
Heatsink (H) The unit is built as standard with a aluminum baseplate as described in the mechanical data. The converter can be delivered with a 15mm heatsink
Ruggedized (M) The unit can be ruggedized to meet MIL-STD810E, MIL-STD461E CE102. M opton with 12 and 24Vin will comply with MIL STD 1275A on DAA and DBB only.
-40°C operation (T) The thermal grade of the components are comply with low ambient temperature.
Conformal coating (V) During manufacturing process components and pcb are covered with an acrylic coating to address high level of ambiant humidity application.
ENVIRONMENTAL
Damp heat MIL STD 810 Proc. 507-2
Shock MIL STD 810 Proc. 516.3
Vibrations MIL STD 810 Proc. 514-5
General
Electric strength Input to earth 1500Vrms. Input to output 3000Vrms. Output to earth 500Vrms
Insulation resistance >100Mohms.
STANDARDS
Safety standards Built to meet IEC60950-1, EN60950-1.
Railway application Designed to meet EN50155, EN50121
Electromagnetic immunity
Supply surge EN50155.
Direct transients EN50155
Surges EN61000-4-5.
Electrostatic discharge EN61000-4-2.
Fast transients/burst EN61000-4-4
DAA_DAB_DAC_Series_Datasheet.pdf
PRBX_Part_number_configurator.xlsm

Find the Right Model

Model Number Input Voltage (Vdc) Output Voltage (Vdc) Output Current (A)
product variant DAB24-3V375W 24Vdc: 9-36Vdc 3.3Vdc: 1.65-3.63Vdc 22.7A
product variant DAB24-575W 24Vdc: 9-36Vdc 5Vdc: 2.5-5.5Vdc 15A
product variant DAB24-12125W 24Vdc: 9-36Vdc 12Vdc: 6-13.2Vdc 10.4A
product variant DAB24-15150W 24Vdc: 9-36Vdc 15Vdc: 7.5-16.5Vdc 10A
product variant DAB24-24150W 24Vdc: 9-36Vdc 24Vdc: 12-26.4Vdc 6.25A
product variant DAB24-28150W 24Vdc: 9-36Vdc 28Vdc: 14-30.8Vdc 5.3A
product variant DAB24-36-150W 24Vdc: 9-36Vdc 36Vdc: 18-39.6Vdc 4.1A
product variant DAB24-48150W 24Vdc: 9-36Vdc 48Vdc: 24-52.8Vdc 3.1A
product variant DAB24-3V3100 24Vdc: 18-36Vdc 3.3Vdc: 1.65-3.63Vdc 30A
product variant DAB24-3V3150 24Vdc: 18-36Vdc 3.3Vdc: 1.65-3.63Vdc 45A
product variant DAB24-5150 24Vdc: 18-36Vdc 5Vdc: 2.5-5.5Vdc 30A
product variant DAB24-5200 24Vdc: 18-36Vdc 5Vdc: 2.5-5.5Vdc 40A
product variant DAB24-6V5100 24Vdc: 18-36Vdc 6.5Vdc: 3.25-7.15Vdc 30.5A
product variant DAB24-8200 24Vdc: 18-36Vdc 8Vdc: 4-8.8Vdc 25A
product variant DAB24-12150 24Vdc: 18-36Vdc 12Vdc: 6-13.2Vdc 12.5A
product variant DAB24-12200 24Vdc: 18-36Vdc 12Vdc: 6-13.2Vdc 16.6A
product variant DAB24-12250 24Vdc: 18-36Vdc 12Vdc: 6-13.2Vdc 20.8A
product variant DAB24-15150 24Vdc: 18-36Vdc 15Vdc: 7.5-16.5Vdc 10A
product variant DAB24-15200 24Vdc: 18-36Vdc 15Vdc: 7.5-16.5Vdc 13.3A
product variant DAB24-24150 24Vdc: 18-36Vdc 24Vdc: 12-26.4Vdc 6.25A
product variant DAB24-24200 24Vdc: 18-36Vdc 24Vdc: 12-26.4Vdc 8.33A
product variant DAB24-24250 24Vdc: 18-36Vdc 24Vdc: 12-26.4Vdc 10.4A
product variant DAB24-28150 24Vdc: 18-36Vdc 28Vdc: 14-30.8Vdc 5.3A
product variant DAB24-28200 24Vdc: 18-36Vdc 28Vdc: 14-30.8Vdc 7.1A
product variant DAB24-28250 24Vdc: 18-36Vdc 28Vdc: 14-30.8Vdc 8.9A
product variant DAB24-36150 24Vdc: 18-36Vdc 36Vdc: 18-39.6Vdc 4.17A
product variant DAB24-36200 24Vdc: 18-36Vdc 36Vdc: 18-39.6Vdc 5.5A
product variant DAB24-48150 24Vdc: 18-36Vdc 48Vdc: 24-52.8Vdc 3.1A
product variant DAB24-48200 24Vdc: 18-36Vdc 48Vdc: 24-52.8Vdc 4.1A

Need help finding the right product model?