DC/DC Converters

Polyamp PU300 SERIES DC/DC Converter

The Polyamp PU300 Series DC/DC Converter is a compact and reliable power solution for industrial, railway, and telecommunications applications. Delivering up to 300W of power, it is engineered to provide consistent performance in demanding environments.

Read More

Features

  • 216W - 300W
  • Industrial grade converter optimised input voltage ranges
  • Input ranges from 10 to 270Vdc
  • Single outputs from 12 to 60Vdc
  • Reverse input voltage protection
  • Fully encapsulated meets IP20
Specifications
INPUT
Input voltages A: 10-30Vdc
B: 20-60Vdc
C: 50-150Vdc
D: 90-270Vdc
OUTPUT
Output voltages See Selection Table
Adjustment range 95%–110%, Adjustment with 15 turn potentiometer
Output ripple Typ 15mVp-p (80kHz)
Source regulation 0.001
Load regulation 0.2% (0 - 100%) load
Temperature coefficient 0.02% per °C
Current limit 105% Rectangular
Remote sense Yes
Transient recovery <3ms. Load step to within 3% of nominal output voltage for 10% to 90%
Soft start Yes
Startup time, type 1 sec.
Holdup time 2–25ms
Efficiency 77%–88%
Design topology Push-pull
Switching frequency 40kH
PROTECTION
Reverse input voltage protection Parallel diode, Code (A) (B) (24) (48)
Series diode, Code (C) (D) (110) (220)
Isolation Input- Output: 2kVdc (input code A,B)
Input- Output: 2.5kVac / 4kVdc (input code C,D)
Input- Case: 2kVdc (input code A,B)
Input- Case: 2.5kVac / 4kVdc (input code C,D) Output- Case: 2kVdc (all outputs)
ENVIRONMENTAL
Operating temperature Range at 100% load: -25°C to +55°C 100% load
Conduction cooling width:260px; height:27px">With derating: -25°C to +70°C
Storage temperature range -40°C to +85°C
FEATURES
Overvoltage protection OVP The output voltage is limited to 15% over nominal output voltage by a extra regulated circuit
Voltage Sense External output voltage sense used when the voltage regulation at the load is critical. The sense can compensate voltage drops up to 5% of the nominal voltage
Remote sense External sense is used when the voltage regulation at the loa is critical. The sense can compensate voltage drops up to 5% of nominal voltage
Extra Output with series diode Use the series diode output when the output is connected in parallel with other power suppies to achieve redundancy
Voltage Alarm Over / Under voltage alarm built in relay changes state if converter output voltage is not with 90% to 115% of nominal output. User selects NO or NC relay function. The relay is rated 30V 0.5A
OPTIONAL FEATURES
Conformal coating For environment with high non condensing humidity, max 98% RH
Inrush current Inrush current limit with NTC, reduces the inrush current during start up. The input votlage range will be affected. Only available on C & D inputs.
Mounting Options See Technical Illustrations
STANDARDS AND APPROVALS
Safety standards IEC950, EN60950, CE LVD 73/23/EEC
C-Tick AS/NZS CISPR11 Group 1, Class A
EMC standards EN/IEC 61000-6-2, EN/IEC 61000-4-2,
EN/IEC 61000-4-3, EN/IEC 61000-4-4,
EN/IEC 61000-4-5, EN/IEC 61000-4-6
EMI standards EN/IEC 61000-6-3
EN55011/EN55022 Level B
MECHANICAL
Dimensions 86 x 210 x 232mm, See Technical Illustration
Weight 4.2kg
Mounting brackets Supplied with L86-1 mounting bracket
See Technical Illustration
Selection Table
MODEL NUMBER INPUT OUTPUT CURRENT OUTPUT POWER
PU300A12 10-30V 12V 18A 216W
PU300A13.8 10-30V 13.8V 16A 220W
PU300A15 10-30V 15V 16A 240W
PU300A24 10-30V 24V 10A 240W
PU300A28 10-30V 28V 8.58A 240W
PU300A36 10-30V 36V 6.67A 240W
PU300A48 10-30V 48V 5A 240W
PU300A60 10-30V 60V 4A 240W
PU300B12 20-60V 12V 25A 300W
PU300B13.8 20-60V 13.8V 21.8A 300W
PU300B15 20-60V 15V 20A 300W
PU300B24 20-60V 24V 12.5A 300W
PU300B28 20-60V 28V 10.8A 300W
PU300B36 20-60V 36V 8.34A 300W
PU300B48 20-60V 48V 6.25A 300W
PU300B60 20-60V 60V 5A 300W
PU300C12 50-150V 12V 25A 300W
PU300C13.8 50-150V 13.8V 21.8A 300W
PU300C15 50-150V 15V 20A 300W
PU300C24 50-150V 24V 12.5A 300W
PU300C28 50-150V 28V 10.8A 300W
PU300C36 50-150V 36V 8.34A 300W
PU300C48 50-150V 48V 6.25A 300W
PU300C60 50-150V 60V 5A 300W
PU300D12 90-270V 12V 25A 300W
PU300D13.8 90-270V 13.8V 21.8A 300W
PU300D15 90-270V 15V 20A 300W
PU300D24 90-270V 24V 12.5A 300W
PU300D28 90-270V 28V 10.8A 300W
PU300D36 90-270V 36V 8.34A 300W
PU300D48 90-270V 48V 6.25A 300W
PU300D60 90-270V 60V 5A 300W
Technical Illustrations
Downloads
pu300-series-datasheet.pdf
INPUT
Input voltages A: 10-30Vdc
B: 20-60Vdc
C: 50-150Vdc
D: 90-270Vdc
OUTPUT
Output voltages See Selection Table
Adjustment range 95%–110%, Adjustment with 15 turn potentiometer
Output ripple Typ 15mVp-p (80kHz)
Source regulation 0.001
Load regulation 0.2% (0 - 100%) load
Temperature coefficient 0.02% per °C
Current limit 105% Rectangular
Remote sense Yes
Transient recovery <3ms. Load step to within 3% of nominal output voltage for 10% to 90%
Soft start Yes
Startup time, type 1 sec.
Holdup time 2–25ms
Efficiency 77%–88%
Design topology Push-pull
Switching frequency 40kH
PROTECTION
Reverse input voltage protection Parallel diode, Code (A) (B) (24) (48)
Series diode, Code (C) (D) (110) (220)
Isolation Input- Output: 2kVdc (input code A,B)
Input- Output: 2.5kVac / 4kVdc (input code C,D)
Input- Case: 2kVdc (input code A,B)
Input- Case: 2.5kVac / 4kVdc (input code C,D) Output- Case: 2kVdc (all outputs)
ENVIRONMENTAL
Operating temperature Range at 100% load: -25°C to +55°C 100% load
Conduction cooling width:260px; height:27px">With derating: -25°C to +70°C
Storage temperature range -40°C to +85°C
FEATURES
Overvoltage protection OVP The output voltage is limited to 15% over nominal output voltage by a extra regulated circuit
Voltage Sense External output voltage sense used when the voltage regulation at the load is critical. The sense can compensate voltage drops up to 5% of the nominal voltage
Remote sense External sense is used when the voltage regulation at the loa is critical. The sense can compensate voltage drops up to 5% of nominal voltage
Extra Output with series diode Use the series diode output when the output is connected in parallel with other power suppies to achieve redundancy
Voltage Alarm Over / Under voltage alarm built in relay changes state if converter output voltage is not with 90% to 115% of nominal output. User selects NO or NC relay function. The relay is rated 30V 0.5A
OPTIONAL FEATURES
Conformal coating For environment with high non condensing humidity, max 98% RH
Inrush current Inrush current limit with NTC, reduces the inrush current during start up. The input votlage range will be affected. Only available on C & D inputs.
Mounting Options See Technical Illustrations
STANDARDS AND APPROVALS
Safety standards IEC950, EN60950, CE LVD 73/23/EEC
C-Tick AS/NZS CISPR11 Group 1, Class A
EMC standards EN/IEC 61000-6-2, EN/IEC 61000-4-2,
EN/IEC 61000-4-3, EN/IEC 61000-4-4,
EN/IEC 61000-4-5, EN/IEC 61000-4-6
EMI standards EN/IEC 61000-6-3
EN55011/EN55022 Level B
MECHANICAL
Dimensions 86 x 210 x 232mm, See Technical Illustration
Weight 4.2kg
Mounting brackets Supplied with L86-1 mounting bracket
See Technical Illustration
MODEL NUMBER INPUT OUTPUT CURRENT OUTPUT POWER
PU300A12 10-30V 12V 18A 216W
PU300A13.8 10-30V 13.8V 16A 220W
PU300A15 10-30V 15V 16A 240W
PU300A24 10-30V 24V 10A 240W
PU300A28 10-30V 28V 8.58A 240W
PU300A36 10-30V 36V 6.67A 240W
PU300A48 10-30V 48V 5A 240W
PU300A60 10-30V 60V 4A 240W
PU300B12 20-60V 12V 25A 300W
PU300B13.8 20-60V 13.8V 21.8A 300W
PU300B15 20-60V 15V 20A 300W
PU300B24 20-60V 24V 12.5A 300W
PU300B28 20-60V 28V 10.8A 300W
PU300B36 20-60V 36V 8.34A 300W
PU300B48 20-60V 48V 6.25A 300W
PU300B60 20-60V 60V 5A 300W
PU300C12 50-150V 12V 25A 300W
PU300C13.8 50-150V 13.8V 21.8A 300W
PU300C15 50-150V 15V 20A 300W
PU300C24 50-150V 24V 12.5A 300W
PU300C28 50-150V 28V 10.8A 300W
PU300C36 50-150V 36V 8.34A 300W
PU300C48 50-150V 48V 6.25A 300W
PU300C60 50-150V 60V 5A 300W
PU300D12 90-270V 12V 25A 300W
PU300D13.8 90-270V 13.8V 21.8A 300W
PU300D15 90-270V 15V 20A 300W
PU300D24 90-270V 24V 12.5A 300W
PU300D28 90-270V 28V 10.8A 300W
PU300D36 90-270V 36V 8.34A 300W
PU300D48 90-270V 48V 6.25A 300W
PU300D60 90-270V 60V 5A 300W
pu300-series-datasheet.pdf

Find the Right Model

Model Number Input Voltage (Vdc) Output Voltage (Vdc) Output Current (A)
product variant PU300A12 12/24Vdc: 10...30Vdc 12Vdc 18A
product variant PU300A13.8 12/24Vdc: 10...30Vdc 13.8Vdc 16A
product variant PU300A24 12/24Vdc: 10...30Vdc 24Vdc 10A
product variant PU300A28 12/24Vdc: 10...30Vdc 28Vdc 8.6A
product variant PU300A48 12/24Vdc: 10...30Vdc 48Vdc 5A
product variant PU300B12 24/36/48Vdc: 20...60Vdc 12Vdc 25A
product variant PU300B13.8 24/36/48Vdc: 20...60Vdc 13.8Vdc 21.8A
product variant PU300B15 24/36/48Vdc: 20...60Vdc 15Vdc 20A
product variant PU300B24 24/36/48Vdc: 20...60Vdc 24Vdc 12.5A
product variant PU300B28 24/36/48Vdc: 20...60Vdc 28Vdc 10.8A
product variant PU300B36 24/36/48Vdc: 20...60Vdc 36Vdc 6.67A
product variant PU300B48 24/36/48Vdc: 20...60Vdc 48Vdc 6.25A
product variant PU300B60 24/36/48Vdc: 20...60Vdc 60Vdc 5A
product variant PU300C12 60/72/110Vdc: 50...150Vdc 12Vdc 25A
product variant PU300C13.8 60/72/110Vdc: 50...150Vdc 13.8Vdc 21.8A
product variant PU300C15 60/72/110Vdc: 50...150Vdc 15Vdc 20A
product variant PU300C24 60/72/110Vdc: 50...150Vdc 24Vdc 12.5A
product variant PU300C28 60/72/110Vdc: 50...150Vdc 28Vdc 10.8A
product variant PU300C48 60/72/110Vdc: 50...150Vdc 48Vdc 6.25A
product variant PU300C60 60/72/110Vdc: 50...150Vdc 60Vdc 5A
product variant PU300D12 110/220Vdc: 90...270Vdc 12Vdc 25A
product variant PU300D13.8 110/220Vdc: 90...270Vdc 13.8Vdc 21.8A
product variant PU300D15 110/220Vdc: 90...270Vdc 15Vdc 20A
product variant PU300D24 110/220Vdc: 90...270Vdc 24Vdc 12.5A
product variant PU300D28 110/220Vdc: 90...270Vdc 28Vdc 10.8A
product variant PU300D48 110/220Vdc: 90...270Vdc 48Vdc 6.25A
product variant PU300D60 110/220Vdc: 90...270Vdc 60Vdc 5A