Site Management and Remote Monitoring and DC Power Systems
Delta Eltek Smartpack R Controller
The Eltek Smartpack R Controller is a retrofit power system controller designed as a direct replacement for the first-generation Eltek Smartpack controllers used in mid-range power systems from 2005 to 2018. It provides a modernised control platform with enhanced monitoring, communication, and cybersecurity capabilities, while maintaining full backward compatibility in form, fit, and function.
Read MoreFeatures
- Backward-compatible replacement for first-generation Eltek Smartpack controllers and legacy systems
- Supports all Eltek power modules, including Rectiverters and CAN Nodes
- Ethernet and SNMPv3 connectivity for secure remote monitoring and control
- MODBUS RTU/TCP support for seamless integration with SCADA and third-party systems
- Compact 1U form factor with an intuitive local LCD display
Specifications
Downloads
| MANUFACTURER PART NUMBER | |
|---|---|
| Model | Smartpack R |
| Manufacturer Part Number | 242100.12 |
| Compatible Delta Eltek Systems | The Smartpack R is a replacement for the first generation Smartpack 1 controllers, manufactured and sold between 2005 to 2018, meant first and foremost for retrofitting of mid-range Eltek power systems from that period. It has the same form factor, i.e. the same dimensions and connections as the original Smartpack 1 and is fully backwards compatible. |
| INPUT DATA | |
|---|---|
| Voltage (Nominal) | 10...75Vdc |
| Power Consumption | 3W (Display = Sleep, no dist. CAN power, LVD activiation, no USB power) 25W (Display = on), dist. CAN power, LVD activation, USB power) |
| SYSTEM CONNECTIONS / SYSTEM MONITORS | |
|---|---|
| Voltage Sense (System Voltage Support) | 12Vdc, 24Vdc, 48Vdc & 60Vdc |
| Current Sense (Shunt Support) | 0 - 20mV, 0-50mV, 0 - 60mV and 0-100mV |
| Battery Fuse Monitoring | Auxiliary switch NO/NC, Pull up/down |
| Load Fuse Monitoring | Auxiliary switch NO/NC, Diode Matrix Pull up/down |
| Battery Temperature Monitoring | AD590 sensor input |
| Battery Symmetry Monitoring (Built In) | 4 x Analog Voltage [0-75V] inputs (12, 24 or 60V blocks) |
| SYSTEM CONNECTIONS - LVD CONTROL | |
|---|---|
| Battery Disconnect | 1 (latched or non-latched supported) |
| Load Disconnect | 2 (latched or non-latched supported) |
| INPUTS & OUTPUTS | |
|---|---|
| Digital Configurations (Inputs #1 - 6) | Auxiliary switch: NO/NC |
| Analog Configurations (Inputs #1 - 2) | Analog Voltage [0-75V] (Configure as NO, NC, Diode Matrix sense or Voltage sense). |
| Analog Configurations (Inputs #3 - 6) | Analog Voltage [0-75V] (Configure as NO, NC, Diode Matrix sense or Voltage sense) Support: Temperature sense w/ NTC probe. |
| Output Configurations - Alarms (Outputs #1 - 6) | 6 x Relay–Dry/Form C - Configurable Normally Open/Closed [Max capacity 75V/2A/60W] |
| CONTROL SYSTEM CONNECTIONS | |
|---|---|
| CAN Power | Distributed CAN Power available +/- 500mA |
| CAN Nodes | Support: I/O Monitors, Battery String Monitor, Load/Current Monitor, Fleximonitor, AC Mains Monitor & Smartnode (legacy) |
| USER INTERFACE | |
|---|---|
| Local | Alphanumeric LCD display (Chinese Traditional and Simplified supported) & 3 Keys |
| Ethernet Port (eth 0: LAN port) (eth 1: Craft port w/DHCP, USB Device port) |
10/100 BASE-T (optional: 1000 BASE-T) IPv4/v6 IP protocols: HTTP (HTML5 Responsive User Interface) / SSL(TLS w/ self-signed certificate generator or load authenticated certificates), SNMP v3 w/Generic MIBs & Enterprise MIB type: SP2-MIB (Eltek Branch 10), MODBUS TCP and pComm UDP (PowerSuite), VPN, VLAN, NTP, SFTP & RADIUS |
| USB Host | Flash Drive for SWFW upgrade and XML configuration file loading Config read from Smartpack 1 Gen USB Device port wlan0: WiFi dongle for wireless craft port, wwan0: 4G USB Cellular Modem eth2: Ethernet Gigabit |
| USB Device | PC – pComm – Windows PowerSuite |
| Serial Port | RS-232 and RS-485 on RJ11 connector Serial protocols: MODBUS RTU Slave, MODBUS RTU/ASCII Master (several pre-defined types and full generic configurable data reader available), Modem Call-Back/SMS reporting (PSTN or GSM) and pComm (PowerSuite) |
| GENERAL SPECIFICATIONS | |
|---|---|
| Dimensions (WxHxD) | 109 x 44 x 156 mm (Chassis dept: 140 mm) |
| Operating Temperature Range | Operating -20 to +65˚C |
| DESIGN STANDARDS | |
|---|---|
| Electrical safety | UL 60950-1, 2ed, 2014-10-14, EN 60950-1:2006/A2:2013 |
| EMC | ETSI EN 300 386 V.2.1.1, EN 61000-6-1(2007) /-2(2005) /-3(2012) /-4(2011), FCC CFR47 Part 15B section 109: 2010 |
| Environment | ETSI EN 300 019: 2-1 v2.3.1 (Class 1.2), 2-2 v2.4.1 (Class 2.3) & 2-3 v2.4.1 (Class 3.2) 2011/65/EU (RoHS) & 2012/19/EU (WEEE) Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised |
| MANUFACTURER PART NUMBER | |
|---|---|
| Model | Smartpack R |
| Manufacturer Part Number | 242100.12 |
| Compatible Delta Eltek Systems | The Smartpack R is a replacement for the first generation Smartpack 1 controllers, manufactured and sold between 2005 to 2018, meant first and foremost for retrofitting of mid-range Eltek power systems from that period. It has the same form factor, i.e. the same dimensions and connections as the original Smartpack 1 and is fully backwards compatible. |
| INPUT DATA | |
|---|---|
| Voltage (Nominal) | 10...75Vdc |
| Power Consumption | 3W (Display = Sleep, no dist. CAN power, LVD activiation, no USB power) 25W (Display = on), dist. CAN power, LVD activation, USB power) |
| SYSTEM CONNECTIONS / SYSTEM MONITORS | |
|---|---|
| Voltage Sense (System Voltage Support) | 12Vdc, 24Vdc, 48Vdc & 60Vdc |
| Current Sense (Shunt Support) | 0 - 20mV, 0-50mV, 0 - 60mV and 0-100mV |
| Battery Fuse Monitoring | Auxiliary switch NO/NC, Pull up/down |
| Load Fuse Monitoring | Auxiliary switch NO/NC, Diode Matrix Pull up/down |
| Battery Temperature Monitoring | AD590 sensor input |
| Battery Symmetry Monitoring (Built In) | 4 x Analog Voltage [0-75V] inputs (12, 24 or 60V blocks) |
| SYSTEM CONNECTIONS - LVD CONTROL | |
|---|---|
| Battery Disconnect | 1 (latched or non-latched supported) |
| Load Disconnect | 2 (latched or non-latched supported) |
| INPUTS & OUTPUTS | |
|---|---|
| Digital Configurations (Inputs #1 - 6) | Auxiliary switch: NO/NC |
| Analog Configurations (Inputs #1 - 2) | Analog Voltage [0-75V] (Configure as NO, NC, Diode Matrix sense or Voltage sense). |
| Analog Configurations (Inputs #3 - 6) | Analog Voltage [0-75V] (Configure as NO, NC, Diode Matrix sense or Voltage sense) Support: Temperature sense w/ NTC probe. |
| Output Configurations - Alarms (Outputs #1 - 6) | 6 x Relay–Dry/Form C - Configurable Normally Open/Closed [Max capacity 75V/2A/60W] |
| CONTROL SYSTEM CONNECTIONS | |
|---|---|
| CAN Power | Distributed CAN Power available +/- 500mA |
| CAN Nodes | Support: I/O Monitors, Battery String Monitor, Load/Current Monitor, Fleximonitor, AC Mains Monitor & Smartnode (legacy) |
| USER INTERFACE | |
|---|---|
| Local | Alphanumeric LCD display (Chinese Traditional and Simplified supported) & 3 Keys |
| Ethernet Port (eth 0: LAN port) (eth 1: Craft port w/DHCP, USB Device port) |
10/100 BASE-T (optional: 1000 BASE-T) IPv4/v6 IP protocols: HTTP (HTML5 Responsive User Interface) / SSL(TLS w/ self-signed certificate generator or load authenticated certificates), SNMP v3 w/Generic MIBs & Enterprise MIB type: SP2-MIB (Eltek Branch 10), MODBUS TCP and pComm UDP (PowerSuite), VPN, VLAN, NTP, SFTP & RADIUS |
| USB Host | Flash Drive for SWFW upgrade and XML configuration file loading Config read from Smartpack 1 Gen USB Device port wlan0: WiFi dongle for wireless craft port, wwan0: 4G USB Cellular Modem eth2: Ethernet Gigabit |
| USB Device | PC – pComm – Windows PowerSuite |
| Serial Port | RS-232 and RS-485 on RJ11 connector Serial protocols: MODBUS RTU Slave, MODBUS RTU/ASCII Master (several pre-defined types and full generic configurable data reader available), Modem Call-Back/SMS reporting (PSTN or GSM) and pComm (PowerSuite) |
| GENERAL SPECIFICATIONS | |
|---|---|
| Dimensions (WxHxD) | 109 x 44 x 156 mm (Chassis dept: 140 mm) |
| Operating Temperature Range | Operating -20 to +65˚C |
| DESIGN STANDARDS | |
|---|---|
| Electrical safety | UL 60950-1, 2ed, 2014-10-14, EN 60950-1:2006/A2:2013 |
| EMC | ETSI EN 300 386 V.2.1.1, EN 61000-6-1(2007) /-2(2005) /-3(2012) /-4(2011), FCC CFR47 Part 15B section 109: 2010 |
| Environment | ETSI EN 300 019: 2-1 v2.3.1 (Class 1.2), 2-2 v2.4.1 (Class 2.3) & 2-3 v2.4.1 (Class 3.2) 2011/65/EU (RoHS) & 2012/19/EU (WEEE) Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised |
Find the Right Model
| Model Number | Input Voltage (Vdc) | ||
|---|---|---|---|
|
Smartpack R | 10 - 75Vdc |
Need help finding the right product model?
