Laboratory Power Supplies
Delta Elektronika ES300 SERIES Laboratory Power Supply
The Delta Elektronika ES300 Series is a high-precision power supply engineered to meet the demands of laboratory and industrial applications requiring stable and reliable DC power. Delivering up to 300W of output, with a voltage range of 0–30V and a current range of 0–10A, the ES300 ensures accurate performance for sensitive tasks. Its compact and lightweight design makes it suitable for 19” rack mounting or standalone use, even in limited spaces.
Read MoreFeatures
- 300W Laboratory Supply
- 0 to 30Vdc and 0 - 10A
- Very Low Output Ripple
- EMC surpasses CE requirements
- Low emissions & high immunity
- High programming speed
Specifications
Technical Illustrations
Downloads
INPUT | |
---|---|
Input voltages | 90 - 265Vac Fuse 5 A T |
Input Frequency | 48 - 62Hz |
Power Factor | Better than 0.97 |
Inrush Current | Limited with NTC resistor of 16 ohms cold resistance |
PROGRAMMING | |
---|---|
V and I control | 10-turn potmeters, res 0.03% |
Programming Inputs | Voltage: 0-5V, offset -3 to +10mV full scale error +/-0.2% Current: 0-5V, offset 0 to +20mV full scale error +/-0.5% Input impedance 1Mohm |
Prog. response time | Up to 0-30V, 1ms Down 30-5V 2ms with load 3 Ohm |
OUTPUT | |
---|---|
Output Voltage | 0 to 30Vdc |
Output Current | 0 to 10A |
Digital Meters | 0 - 30.0V / 0 - 10.00A, 0.5% + 2 dig |
Monitor Voltage | Voltage: 0 - 5V, offset 0 to +7mV, full scale error +/-0.2% |
Monitor Current | Current: 0 - 5V, offset -5 to 0mV, full scale error+/-0.5% |
Reference Voltage | 5.165V +/-31mV, TC12ppm typ, 30ppm max |
CC status output | +5V (or 5mA) when in CC mode |
Limits | Voltage adjust range: 0 - 102% Current adjust range: 0 - 102% |
Voltage Regulation | Load 0 - 100%, 10mV Line 100-260Vac 1mV |
Current Regulation | Load 0 - 100%, 4mA Line 200-26VAC, 1mA |
Ripple & Noise | CV: 5mV rms, 15mV p-p CC: 6mA rms, 15mA p-p |
Output Impedance | Less than 0.3ohm up to 100kHz(I out > 0.5A) |
Recovery Time | 50 µs (after 50-100% load step) |
Hold up time | 18 ms full load, 50 ms half load |
Remote Sensing | Is not provided |
Over voltage limit | Fixed at 34V (int. adjust, 6-34V) |
Thermal protection | Shuts down output in case of insufficient cooling |
OPTIONAL FEATURES | |
---|---|
Software Control and Interfaces | P179 - Ethernet controller (incl sequencer) P180 - RS232 controller P281 - PROFIBUS contoller P282 - CANBUS controller |
External programming interface modules | IEEE488 controller module ISO AMP module |
OPERATING | |
---|---|
Efficiency | > 86% |
Remote ShutDown | +5V (3.5 - 12V) or relay contact, response time 3ms |
Series Operation | Normal and Master/Slave series operation is possible. For fast and easy operation the M/S Series Adapter is recommended |
Parallel Operation | No limitations. Normal and Master/Slave parallel operation is possible |
Insulation | Input to Output: 4.0KVAC (1 min) Input to Case: 2.5KVAC (1 min) Output to Case: 600VDC |
MTBF | 500,000 hrs |
Operating Temperature | -20°C to +50°C |
Storage Temperature | -40°C to +85°C |
MECHANICAL | |
---|---|
Dimensions | 52 x 224 x 333mm |
Weight | 3.1kg |
Degree of Protection | Enclosure IP20 |
STANDARDS AND APPROVALS | |
---|---|
Safety | EN60950 / EN61010 Current adjust range: 0 - 102% |
EMC | EN61204-3 Power Supply Standard EN61000-6-3 (EN55022B) Generic Emission EN61000-6-2 Generic Immunity |

INPUT | |
---|---|
Input voltages | 90 - 265Vac Fuse 5 A T |
Input Frequency | 48 - 62Hz |
Power Factor | Better than 0.97 |
Inrush Current | Limited with NTC resistor of 16 ohms cold resistance |
PROGRAMMING | |
---|---|
V and I control | 10-turn potmeters, res 0.03% |
Programming Inputs | Voltage: 0-5V, offset -3 to +10mV full scale error +/-0.2% Current: 0-5V, offset 0 to +20mV full scale error +/-0.5% Input impedance 1Mohm |
Prog. response time | Up to 0-30V, 1ms Down 30-5V 2ms with load 3 Ohm |
OUTPUT | |
---|---|
Output Voltage | 0 to 30Vdc |
Output Current | 0 to 10A |
Digital Meters | 0 - 30.0V / 0 - 10.00A, 0.5% + 2 dig |
Monitor Voltage | Voltage: 0 - 5V, offset 0 to +7mV, full scale error +/-0.2% |
Monitor Current | Current: 0 - 5V, offset -5 to 0mV, full scale error+/-0.5% |
Reference Voltage | 5.165V +/-31mV, TC12ppm typ, 30ppm max |
CC status output | +5V (or 5mA) when in CC mode |
Limits | Voltage adjust range: 0 - 102% Current adjust range: 0 - 102% |
Voltage Regulation | Load 0 - 100%, 10mV Line 100-260Vac 1mV |
Current Regulation | Load 0 - 100%, 4mA Line 200-26VAC, 1mA |
Ripple & Noise | CV: 5mV rms, 15mV p-p CC: 6mA rms, 15mA p-p |
Output Impedance | Less than 0.3ohm up to 100kHz(I out > 0.5A) |
Recovery Time | 50 µs (after 50-100% load step) |
Hold up time | 18 ms full load, 50 ms half load |
Remote Sensing | Is not provided |
Over voltage limit | Fixed at 34V (int. adjust, 6-34V) |
Thermal protection | Shuts down output in case of insufficient cooling |
OPTIONAL FEATURES | |
---|---|
Software Control and Interfaces | P179 - Ethernet controller (incl sequencer) P180 - RS232 controller P281 - PROFIBUS contoller P282 - CANBUS controller |
External programming interface modules | IEEE488 controller module ISO AMP module |
OPERATING | |
---|---|
Efficiency | > 86% |
Remote ShutDown | +5V (3.5 - 12V) or relay contact, response time 3ms |
Series Operation | Normal and Master/Slave series operation is possible. For fast and easy operation the M/S Series Adapter is recommended |
Parallel Operation | No limitations. Normal and Master/Slave parallel operation is possible |
Insulation | Input to Output: 4.0KVAC (1 min) Input to Case: 2.5KVAC (1 min) Output to Case: 600VDC |
MTBF | 500,000 hrs |
Operating Temperature | -20°C to +50°C |
Storage Temperature | -40°C to +85°C |
MECHANICAL | |
---|---|
Dimensions | 52 x 224 x 333mm |
Weight | 3.1kg |
Degree of Protection | Enclosure IP20 |
STANDARDS AND APPROVALS | |
---|---|
Safety | EN60950 / EN61010 Current adjust range: 0 - 102% |
EMC | EN61204-3 Power Supply Standard EN61000-6-3 (EN55022B) Generic Emission EN61000-6-2 Generic Immunity |

Find the Right Model
Model Number | Input Voltage (Vac) | Output Voltage Range (Vdc) | Output Current Range (A) | ||
---|---|---|---|---|---|
![]() |
ES030-10 | 90...264Vac, 50/60Hz | 0 - 30Vdc | 0 - 10A |
Need help finding the right product model?