DC/DC Converters

Premium CRS-120 SERIES DC/DC Converter

The Premium CRS-120 Series DC/DC Converter is a compact and reliable power solution designed for industrial and railway applications. With an output range of 100–140W, it offers efficient and stable power conversion for critical systems operating in demanding environments.

Read More

Features

  • High input-output isolation
  • Standard size Eurocard 3U
  • Adjustable output voltage
  • Remote sensing
  • Input voltage OK LED
  • Output voltage presence LED
Specifications
INPUT
Voltage range See selection table
Undervoltage shutdown 55% to 60% Vi nom
Max allowed input ripple 15% Vin nom (VRMS at 100Hz)
OUTPUT
Output Voltage See selection table.
Output voltage adjustment -10% ... +15% Vo nom
-10% ... +25% Vo nom for 12V output models
Line regulation (Io = nom) < 0,2 % (Io = nom)
Load regulation (Vin = nom) < 0,2 % (Vin = nom; Io: 0…100%)
Ripple < 50 mVpp
Noise (BW = 20MHz) < 100 mVpp
ENVIRONMENTAL
StorageTemperature -40°C ... 85°C
Operating temperature range at Io= 100% -25°C ... 60°C (-40°C ... 60°C, see note-1)
Operating temperature range at Io=50% -25ºC ... 80ºC(-40°C … 80ºC, see note-1)
Maximum Relative humidity 95% with no condensation
MTBF 500.000h @ 40°C according to IEC61709
EMC
Emission EN61000-6-3
Immunity EN61000-6-2
SAFETY
Safety EN60950-1, EN62368-1
Dielectric strength Input/Output 3000Vac, 4200Vdc 1min
Dielectric strength Input / Earth 1500Vac, 2100Vdc 1min
Dielectric strength Output / Earth 1500Vac, 2100Vdc 1min
MECHANICAL
Approximate weight 430g
Dimensions 100 x 160 x 38.5mm
CONTROL
Remote inhibit range 5V ... 24V
Remote sense < 0.3V per pole
PROTECTIONS
Against overloads and short-circuits Current limiting
Against reverse input voltage Input fuse
Against input under-voltage Under-voltage lock-out
Against Input over-currents Input fuse
Selection Table
PART NUMBER POWER (W) INPUT (V) INPUT RANGE (V) OUTPUT (V) OUTPUT CURRENT (A) EFFICIENCY(%)
CRS-120-6761 100 12 9 - 15 5 20 78
CRS-120-6762 100 12 9 - 15 12 8,3 83
CRS-120-6763 120 12 9 - 15 24 5 84
CRS-120-6764 120 12 9 - 15 48 2,5 85
CRS-120-6765 100 24 18 - 30 5 20 78
CRS-120-6766 120 24 18 - 30 12 10 83
CRS-120-6767 120 24 18 - 30 24 5 84
CRS-120-6768 120 24 18 - 30 48 2.5 85
CRS-120-6769 100 48 36 - 72 5 20 79
CRS-120-6770 120 48 36 - 72 12 10 84
CRS-120-6771 140 48 36 - 72 24 5,83 86
CRS-120-6772 140 48 36 - 72 48 2,92 88
CRS-120-6773 100 72 50,4 - 90 5 20 79
CRS-120-6774 120 72 50,4 - 90 12 10 84
CRS-120-6775 140 72 50,4 - 90 24 5,83 86
CRS-120-6776 140 72 50,4 - 90 48 2,92 88
CRS-120-6777 100 110 77 - 144 5 36 80
CRS-120-6778 120 110 77 - 144 12 20 85
CRS-120-6779 140 110 77 - 144 24 5,83 87
CRS-120-6780 140 110 77 - 144 48 2,92 89
CRS-120-6781 100 220 156 - 275 5 20 80
CRS-120-6782 120 220 156 - 275 12 10 85
CRS-120-6783 140 220 156 - 275 24 5,83 87
CRS-120-6784 140 220 156 - 275 48 2,92 89
Technical Illustrations
Downloads
CRS-120_Datasheet.pdf
INPUT
Voltage range See selection table
Undervoltage shutdown 55% to 60% Vi nom
Max allowed input ripple 15% Vin nom (VRMS at 100Hz)
OUTPUT
Output Voltage See selection table.
Output voltage adjustment -10% ... +15% Vo nom
-10% ... +25% Vo nom for 12V output models
Line regulation (Io = nom) < 0,2 % (Io = nom)
Load regulation (Vin = nom) < 0,2 % (Vin = nom; Io: 0…100%)
Ripple < 50 mVpp
Noise (BW = 20MHz) < 100 mVpp
ENVIRONMENTAL
StorageTemperature -40°C ... 85°C
Operating temperature range at Io= 100% -25°C ... 60°C (-40°C ... 60°C, see note-1)
Operating temperature range at Io=50% -25ºC ... 80ºC(-40°C … 80ºC, see note-1)
Maximum Relative humidity 95% with no condensation
MTBF 500.000h @ 40°C according to IEC61709
EMC
Emission EN61000-6-3
Immunity EN61000-6-2
SAFETY
Safety EN60950-1, EN62368-1
Dielectric strength Input/Output 3000Vac, 4200Vdc 1min
Dielectric strength Input / Earth 1500Vac, 2100Vdc 1min
Dielectric strength Output / Earth 1500Vac, 2100Vdc 1min
MECHANICAL
Approximate weight 430g
Dimensions 100 x 160 x 38.5mm
CONTROL
Remote inhibit range 5V ... 24V
Remote sense < 0.3V per pole
PROTECTIONS
Against overloads and short-circuits Current limiting
Against reverse input voltage Input fuse
Against input under-voltage Under-voltage lock-out
Against Input over-currents Input fuse
PART NUMBER POWER (W) INPUT (V) INPUT RANGE (V) OUTPUT (V) OUTPUT CURRENT (A) EFFICIENCY(%)
CRS-120-6761 100 12 9 - 15 5 20 78
CRS-120-6762 100 12 9 - 15 12 8,3 83
CRS-120-6763 120 12 9 - 15 24 5 84
CRS-120-6764 120 12 9 - 15 48 2,5 85
CRS-120-6765 100 24 18 - 30 5 20 78
CRS-120-6766 120 24 18 - 30 12 10 83
CRS-120-6767 120 24 18 - 30 24 5 84
CRS-120-6768 120 24 18 - 30 48 2.5 85
CRS-120-6769 100 48 36 - 72 5 20 79
CRS-120-6770 120 48 36 - 72 12 10 84
CRS-120-6771 140 48 36 - 72 24 5,83 86
CRS-120-6772 140 48 36 - 72 48 2,92 88
CRS-120-6773 100 72 50,4 - 90 5 20 79
CRS-120-6774 120 72 50,4 - 90 12 10 84
CRS-120-6775 140 72 50,4 - 90 24 5,83 86
CRS-120-6776 140 72 50,4 - 90 48 2,92 88
CRS-120-6777 100 110 77 - 144 5 36 80
CRS-120-6778 120 110 77 - 144 12 20 85
CRS-120-6779 140 110 77 - 144 24 5,83 87
CRS-120-6780 140 110 77 - 144 48 2,92 89
CRS-120-6781 100 220 156 - 275 5 20 80
CRS-120-6782 120 220 156 - 275 12 10 85
CRS-120-6783 140 220 156 - 275 24 5,83 87
CRS-120-6784 140 220 156 - 275 48 2,92 89
CRS-120_Datasheet.pdf

Find the Right Model

Model Number Input Voltage (Vdc) Output Voltage (Vdc) Output Current (A)
product variant CRS-120-6761 12Vdc: 9...15Vdc 5Vdc 20A
product variant CRS-120-6762 12Vdc: 9...15Vdc 12Vdc 8.3A
product variant CRS-120-6763 12Vdc: 9...15Vdc 24Vdc 5A
product variant CRS-120-6764 12Vdc: 9...15Vdc 48Vdc 2.5A
product variant CRS-120-6765 24Vdc: 14.4...30Vdc 5Vdc 20A
product variant CRS-120-6766 24Vdc: 14.4...30Vdc 12Vdc 10A
product variant CRS-120-6767 24Vdc: 14.4...30Vdc 24Vdc 5A
product variant CRS-120-6768 24Vdc: 14.4...30Vdc 48Vdc 2.5A
product variant CRS-120-6769 48Vdc: 28.8...60Vdc 5Vdc 20A
product variant CRS-120-6770 48Vdc: 28.8...60Vdc 12Vdc 10A
product variant CRS-120-6771 48Vdc: 28.8...60Vdc 24Vdc 5.83A
product variant CRS-120-6772 48Vdc: 28.8...60Vdc 48Vdc 2.92A
product variant CRS-120-6773 72Vdc: 43.2...90Vdc 5Vdc 20A
product variant CRS-120-6774 72Vdc: 43.2...90Vdc 12Vdc 10A
product variant CRS-120-6775 72Vdc: 43.2...90Vdc 24Vdc 5.83A
product variant CRS-120-6776 72Vdc: 43.2...90Vdc 48Vdc 2.92A
product variant CRS-120-6777 110Vdc: 66...144Vdc 5Vdc 20A
product variant CRS-120-6778 110Vdc: 66...144Vdc 12Vdc 10A
product variant CRS-120-6779 110Vdc: 66...144Vdc 24Vdc 5.83A
product variant CRS-120-6780 110Vdc: 66...144Vdc 48Vdc 2.92A
product variant CRS-120-6781 220Vdc: 156...275Vdc 5Vdc 20A
product variant CRS-120-6782 220Vdc: 156...275Vdc 12Vdc 10A
product variant CRS-120-6783 220Vdc: 156...275Vdc 24Vdc 5.83A
product variant CRS-120-6784 220Vdc: 156...275Vdc 48Vdc 2.92A