AC/DC Power Supplies

Camtec HPW02401 SERIES AC/DC Power Supply

The Camtec HPW02401 Series AC/DC Power Supply is a high-efficiency, 240W to 312W industrial powerhouse, engineered to meet the demands of complex and dynamic applications. With up to 91.5% efficiency and natural convection cooling, this DIN-rail mounted power supply is designed for galvanic systems, DC drives, and UPS setups. Manufactured in Germany, the HPW02401 Series ensures consistent performance under full load, thanks to its rugged metal housing and reliable circuit design.

Read More

Features

  • 240 Watts Power Supply
  • DIN Rail 35mm. Metal housing
  • 91.5% efficiency. -25°C...+70°C ambient
  • Free air convection
  • Continuous short circuit protected
  • PSU can be used as a battery charger due to constant current
Specifications
GENERAL
Output Voltage See selection table
AC Input Voltage 85..132Vac / 184..265Vac
Frequency 47…63Hz
DC Input Voltage 90…350Vdc
AC Input Current 115Vac <2.6A 230Vac <1.3A
AC Input Current 115Vac <2.6A 230Vac <1.3A
Tolerance Ua adjusted ± 0.5%
Transient Time <1ms (10-100% , 100-10%)
Minimum Load 0 A
Efficiency 91.5% typical
Load Protection 1,2x I rated , auto recovery
Short Circuit Protection Yes
Temperature Controlled Yes (see technical illustrations)
Hold Up Time > 40ms (100...230Vac input)
Inrush Current < 7A (230Vac), active limiter
Softstart 50ms typical
RELIABILITY
Air & Surface Leakage Paths > 8mm
Input/Output Galvanic insulated
DC Fail Relay (galv. insulated) ≤48Vdc/500mA , ≤30Vac/500mA
MTBF (IEC61709) 500000h
ENVIRONMENTAL
Cooling Natural convection
Ambient Temperature - 25°C…+70°C
Storage Temperature - 40°C…+85°C
Relative Humidity 95% (25°C) non-condensing
Pollution Degree 2 (EN50178)
Climatic Class 3k3 (EN60721)
STANDARDS AND APPROVALS
EMI EN55022 class B / EN61000-3-2
EMS EN61000-6-2,3 active PFC
Safety EN60950-1, EN60204-1
Safety class 1(A) VDE0805, VDE0100
MECHANICAL
Dimensions (HxWxD) 130x75x115mm
Weight 1200g
Connectors (AC & DC) AWG20...AWG6 IEC60664-1, IEC61984
Selection Table
DIN RAIL MODEL HPW02401.12T HPW02401.24T HPW02401.36T HPW02401.48T HPW02401.60T HPW02401.72T
Rated DC Voltage 12Vdc 24Vdc 36Vdc 48Vdc 60Vdc 72Vdc
DC Voltage Adjust 9...18Vdc 18..30Vdc 30...43Vdc 43...53Vdc 53...72Vdc 68...86Vdc
Over Voltage Protection 21Vdc 35Vdc 50Vdc 60Vdc 84Vdc 97Vdc
Rated Current 60°C 15.0A 10.0A 6.7A 5.0A 4.0A 3.3A
Rated Current 40°C 19.0A 13.0A 8.7A 6.5A 5.2A 4.3A
Boost 60s/60°C 18.0A 12.0A 8.0A 6.0A 4.8A 4.0A
Ripple mVpp/230Vac 30 (20MHz) 30 (20MHz) 60 (20MHz) 50 (20MHz) 50 (20MHz) 60 (20MHz)
Load regulation 0-100% ±0.5% ±0.2% ±0.2% ±0.2% ±0.2% ±0.2%
WALL MOUNT MODEL HPW02401.12W HPW02401.24W HPW02401.36W HPW02401.48W HPW02401.60W HPW02401.72W
Rated DC Voltage 12Vdc 24Vdc 36Vdc 48Vdc 60Vdc 72Vdc
DC Voltage Adjust 9...18Vdc 18..30Vdc 30...43Vdc 43...53Vdc 53...72Vdc 68...86Vdc
Over Voltage Protection 21Vdc 35Vdc 50Vdc 60Vdc 84Vdc 97Vdc
Rated Current 60°C 15.0A 10.0A 6.7A 5.0A 4.0A 3.3A
Rated Current 40°C 19.0A 13.0A 8.7A 6.5A 5.2A 4.3A
Boost 60s/60°C 18.0A 12.0A 8.0A 6.0A 4.8A 4.0A
Ripple mVpp/230Vac 30 (20MHz) 30 (20MHz) 60 (20MHz) 50 (20MHz) 50 (20MHz) 60 (20MHz)
Load regulation 0-100% ±0.5% ±0.2% ±0.2% ±0.2% ±0.2% ±0.2%

Optional Coating (option C): We offer the HPW-Series with optional coating. It is to be used in e.g. dusty, dirty, high humidity, or in awaiting quick temperature changes. Short circuit and corrosion at print board lines and at solder points can be prevented. The coat itself is a transparent acrylic resin. It is procured with a robotics varnishing machine. Peters SL 1306 N-FLZ (transparent) IEC60216-1 2001, IPC-CC-830B, UL listed as permanent coating FileNo.: E80315 , UL94V-0
Options to be added to the order-code:
C coating
Order samples:
HPW02401.24TC DIN-Rail+Coating
HPW02401.24WC Wallmount+Coating

Technical Illustrations
Downloads
camtec-hpw02401-032022-00-0_datasheet.pdf
GENERAL
Output Voltage See selection table
AC Input Voltage 85..132Vac / 184..265Vac
Frequency 47…63Hz
DC Input Voltage 90…350Vdc
AC Input Current 115Vac <2.6A 230Vac <1.3A
AC Input Current 115Vac <2.6A 230Vac <1.3A
Tolerance Ua adjusted ± 0.5%
Transient Time <1ms (10-100% , 100-10%)
Minimum Load 0 A
Efficiency 91.5% typical
Load Protection 1,2x I rated , auto recovery
Short Circuit Protection Yes
Temperature Controlled Yes (see technical illustrations)
Hold Up Time > 40ms (100...230Vac input)
Inrush Current < 7A (230Vac), active limiter
Softstart 50ms typical
RELIABILITY
Air & Surface Leakage Paths > 8mm
Input/Output Galvanic insulated
DC Fail Relay (galv. insulated) ≤48Vdc/500mA , ≤30Vac/500mA
MTBF (IEC61709) 500000h
ENVIRONMENTAL
Cooling Natural convection
Ambient Temperature - 25°C…+70°C
Storage Temperature - 40°C…+85°C
Relative Humidity 95% (25°C) non-condensing
Pollution Degree 2 (EN50178)
Climatic Class 3k3 (EN60721)
STANDARDS AND APPROVALS
EMI EN55022 class B / EN61000-3-2
EMS EN61000-6-2,3 active PFC
Safety EN60950-1, EN60204-1
Safety class 1(A) VDE0805, VDE0100
MECHANICAL
Dimensions (HxWxD) 130x75x115mm
Weight 1200g
Connectors (AC & DC) AWG20...AWG6 IEC60664-1, IEC61984
DIN RAIL MODEL HPW02401.12T HPW02401.24T HPW02401.36T HPW02401.48T HPW02401.60T HPW02401.72T
Rated DC Voltage 12Vdc 24Vdc 36Vdc 48Vdc 60Vdc 72Vdc
DC Voltage Adjust 9...18Vdc 18..30Vdc 30...43Vdc 43...53Vdc 53...72Vdc 68...86Vdc
Over Voltage Protection 21Vdc 35Vdc 50Vdc 60Vdc 84Vdc 97Vdc
Rated Current 60°C 15.0A 10.0A 6.7A 5.0A 4.0A 3.3A
Rated Current 40°C 19.0A 13.0A 8.7A 6.5A 5.2A 4.3A
Boost 60s/60°C 18.0A 12.0A 8.0A 6.0A 4.8A 4.0A
Ripple mVpp/230Vac 30 (20MHz) 30 (20MHz) 60 (20MHz) 50 (20MHz) 50 (20MHz) 60 (20MHz)
Load regulation 0-100% ±0.5% ±0.2% ±0.2% ±0.2% ±0.2% ±0.2%
WALL MOUNT MODEL HPW02401.12W HPW02401.24W HPW02401.36W HPW02401.48W HPW02401.60W HPW02401.72W
Rated DC Voltage 12Vdc 24Vdc 36Vdc 48Vdc 60Vdc 72Vdc
DC Voltage Adjust 9...18Vdc 18..30Vdc 30...43Vdc 43...53Vdc 53...72Vdc 68...86Vdc
Over Voltage Protection 21Vdc 35Vdc 50Vdc 60Vdc 84Vdc 97Vdc
Rated Current 60°C 15.0A 10.0A 6.7A 5.0A 4.0A 3.3A
Rated Current 40°C 19.0A 13.0A 8.7A 6.5A 5.2A 4.3A
Boost 60s/60°C 18.0A 12.0A 8.0A 6.0A 4.8A 4.0A
Ripple mVpp/230Vac 30 (20MHz) 30 (20MHz) 60 (20MHz) 50 (20MHz) 50 (20MHz) 60 (20MHz)
Load regulation 0-100% ±0.5% ±0.2% ±0.2% ±0.2% ±0.2% ±0.2%

Optional Coating (option C): We offer the HPW-Series with optional coating. It is to be used in e.g. dusty, dirty, high humidity, or in awaiting quick temperature changes. Short circuit and corrosion at print board lines and at solder points can be prevented. The coat itself is a transparent acrylic resin. It is procured with a robotics varnishing machine. Peters SL 1306 N-FLZ (transparent) IEC60216-1 2001, IPC-CC-830B, UL listed as permanent coating FileNo.: E80315 , UL94V-0
Options to be added to the order-code:
C coating
Order samples:
HPW02401.24TC DIN-Rail+Coating
HPW02401.24WC Wallmount+Coating

camtec-hpw02401-032022-00-0_datasheet.pdf

Find the Right Model

Model Number Input Voltage (Vac) Output Voltage (Vdc) Output Current (A)
product variant HPW02401.012T(R2) 85...264Vac 50/60Hz 12Vdc (Adj. 9 - 18Vdc) 15A @ 60°C / 19A @ 40°C
product variant HPW02401.024T(R2) 85...264Vac 50/60Hz 24Vdc (Adj. 18 - 30Vdc 10A @ 60°C / 13A @ 40°C
product variant HPW02401.036T(R2) 85...264Vac 50/60Hz 36VDc (Adj. 30 - 43Vdc) 6.7A @ 60°C / 8.7A @ 40°C
product variant HPW02401.048T(R2) 85...264Vac 50/60Hz 48Vdc (Adj. 43 - 53Vdc) 5A @ 60°C / 6.8A @ 40°C
product variant HPW02401.060T(R2) 85...264Vac 50/60Hz 60Vdc (Adj. 53 - 72Vdc) 4A @ 60°C / 5.2A @ 40°C
product variant HPW02401.072T(R2) 85...264Vac 50/60Hz 72Vdc (Adj. 68 - 86Vdc) 3.3A @ 60°C / 4.3A @ 40°C

Need help finding the right product model?