NOTES |
1. Peak output current with 10% maximum duty cycle for less than 60 seconds.
2. PD110 "M" & "H" series are suitable only for 110W maximum at 20 CFM forced air cooling or 80W maximum at convection cooling. PD110 "L" series are suitable only for 90W maximum at 20 CFM forced air cooling or 70W maximum at convection cooling.
3. Suffix codes for input range, mechanical format and connector are as follows: PD110-X1X2X3X4X5, "X1X2" is the model code from the above table, "X3" is the input range.
(L = 10–20VDC, M = 18–36VDC, H = 36–72VDC), "X4" is the mechanical format (A = open PCB, B = L-bracket, C = enclosed) and "X5" is the input and output connector code
(Blank + Molex KK type, T = miniature terminal block), eg, PD110–31MCT (18–36VDC input range, enclosed format and miniature terminals blocks). |